1.0 Introduction The Premier Elite PSU200 is a standalone intelligent 2.5 Amp power supply. The Premier Elite PSU200XP is a PSU200 combined with a Premier Elite 8XP zone expander to create a fully monitored power supply unit via the control panel network.
2.0 PCB Layout and Terminals The figure below shows the PCB layout of the PSU200 and PSU200XP: Texecom Power Supply Connection. Connector to case tamper switch. Power LED Communication port (for connection to 8XP zone expander). Battery 1 charge current selector (0.75A or 0.30A).
Page 7
Battery 2 charge current selector (0.75A or 0.30A). Battery load test options. 12V supply output. External load for battery load test. Not Used Normally closed tamper output. Number of batteries connected. 12V output protection fuse (1.6A). Battery 1 and 2 connections. Battery kick start switch.
PCB via a jumper plug JP2. When installing a PSU200 the two tamper connections terminals should be connected to the tamper or 24hour zone of the alarm control panel. The tamper connections are not required for the PSU200XP as the tamper status is detected through the communication port.
Page 9
(maximum continuous current) for the required standby period: PSU200 Rated Output (Amps) Battery Arrangement Battery Charge 1 x 7Ah 0.3A 0.53A 0.24A 0.18A 0.071A 2 x 7Ah 0.3A 1.1A 0.53A 0.42A 0.18A 0.3A 1.37A 0.66A 0.52A 0.23A 1 x 17Ah 0.75A...
Page 10
Battery Monitoring Each battery is monitored independently, therefore, the number of batteries connected to the PSU200/PSU200XP must be set using JP8. If JP8 is set to “1 Battery” then battery 2 is not monitored. The following conditions are monitored: INS314-8 10/17...
Page 11
If either battery is disconnected during this test a battery fault is generated. Load: The PSU200 tests the standby batteries every 24 hours by allowing the batteries to power the PSU and connected devices for a period of 10 seconds.
B only = PSU Load + External Load (if any) + 500mA C only = PSU Load + External Load (if any) + 500mA B + C = PSU Load + External Load (if any) + 1A No jumpers fitted is the same as fitting jumper A, ie PSU Load + External Load (if any) (see items - and 9 of Figure...
5.0 Wiring Diagrams PSU200XP Connected to Premier Elite Control Panel For a list of supported control panels, see Introduction. INS314-8 13/17...
Page 14
The PSU200 can be fully monitored by other makes of control panels, by using the fault and tamper terminals. The zones on the control panel will need to be programmed for PSU monitoring functionality. Please consult the manufacturer’s instructions in order to ascertain whether the control panel supports these zone types.
Minimum energy level 100% (to meet the backup periods specified in this of the SD in its charged manual) state Location The PSU200 should be mounted within the supervised premises. Operating temperature -10°C to +50°C Maximum humidity 95% non-condensing Dimensions...
Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Premier Elite PSU200 or PSU200XP failed to function correctly. Due to our policy of continuous improvement Texecom reserve the right to change specification...
Page 17
Premier & Premier Elite are trademarks of Texecom Ltd. INS314-8 17/17...