Download Print this page

Denon AVRX6500HBKE3 Service Manual page 133

Integrated network av receiver/amplifier

Advertisement

When the results of check item (3-16.11.) are "03"
(Detection of HPD is OK / Detection of RXSENSE is OK )
Checking the EDID register. (OUT2)
Check item(3-16.12.).
Check the Monitor EDID :
① Unplug the AC cord. Plug the AC cord into a power outlet.
② Send the transmission command "m_2" from Termite.exe.
Are the first eight bytes of the returned value "00FFFFFFFFFFFF00"?
YES
Check item(3-16.13.).
Checking the TMDS :
Check the TMDS waveform at the following test
point.
N3401
HDMI OUT
[MONITOR2]
YES
NO
Check for a short circuit in the TMDS line.
If there is no problem, the HDMI Tx
[U3401] is faulty.
Replace with a new device.
HDMI Tx [U3401] is faulty.
Replace with a new device.
Recheck from
check item (3.4.)
If it does not work, replace the PCB.
NO
Check item(3-16.14.).
Check communication with
the monitor :
Are waveforms of "DDCSCK" and "DDCSDA"
observed at the test point near the HDMI output
terminal [N3401]?
N3401
HDMI OUT
[MONITOR2]
DDCSCK
DDCSDA
YES
NO
HDMI Tx [U3401] is faulty.
Replace with a new device.
HDMI Tx [U3401] is faulty.
Replace with a new device.
Example
The first eight bytes are normally
"00FFFFFFFFFFFF00".
*If the AVR and the TV are not con-
nected via HDMI, the correct register
value cannot be verified.
less than 100KHz
5V
5V
This diagram shows an example of the DDC commu-
nication waveform.
-The high level voltage is 5V.
-The frequency of the DDC CLK is 100kHz or less.
Check at each test point.
Voltage scale : 2.0V/div
Time scale : 40us/div
133