Router Mode - THOMSON TTN-BES-0808CP/75 Installation Manual

Routing switcher
Table of Contents

Advertisement

BES-0808CP/75
5.2

Router mode

The BES-0808CP/75 router allows switching in different modes. You can choose among:
8x8
4x4
2x2
Switch 5 - 6 on the configuration switch set the router's mode. The Triton Router Control System
software must be configured according to the mode chosen on the router.
The modes can be switched according to the following pattern:
-
means switch down
*
means switch up
Switch
The printed nomenclature on the BES-0808CP/75 router is for use with 8x8 AES/EBU 1 Channel. If one
of the other formats shall be used, please connect the AES/EBU signals according to the following tables.
Default mode is 8x8 AES/EBU 1 Channel.
AES/EBU 1 Channel
Signal
Input
1
2
3
4
5
6
7
8
AES/EBU 2 Channel
Ch1 Signal
Input
1
2
3
4
8
AES/EBU 1 Channel
AES/EBU 2 Channel
AES/EBU 4 Channel
5
6
-
-
-
*
*
-
*
*
Signal
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
Ch1 Signal
1
1
2
2
3
3
4
4
Mode
8x8
AES/EBU 1 Channel
4x4
AES/EBU 2 Channel
2x2
AES/EBU 4 Channel
position is not in use
Output
1
2
3
4
5
6
7
8
Output
1
2
3
4
Rev. 2