Download Print this page

Maytag Amana DT01 Series Installation Instructions Manual page 9

Wireless kits

Advertisement

to obtain the 15/16" needed between the magnet and the sensor mounting plate on the door frame.
THE ALIGNMENT GUIDE
IS AT 15/16" FROM
BACK PLATE.
ALIGNMENT
GUIDES
ON BOTTOM
OF DD01E
SENSOR
MOUNTING
PLATE
IMPORTANT NOTE: When properly installed, the center line mark on the bottom of the DD01E or DD01F will line up with
the center of the line of the magnet holder containing the magnet. Choose magnet position A, B, or C to align the
magnet 15/16" from the back of the DD01E or DD01F .
Door Sensor Operation Verification
NOTE: Do NOT attempt to bind a DD01E unless proper operation has been validated.
To verify that door sensor is installed properly:
1. Install batteries into DD01E OR DD01F and snap sensor onto wall plate.
2. Close the door. Green light in lens should illuminate. Open door and green light will turn off. Repeat this step
several times to ensure door sensor is operating correctly.
Procedure must be accomplished within one minute. If not accomplished within one minute, remove batteries and
repeat Steps 1 & 2.
Configuration Settings
The PTAC control will automatically self-configure to work with the wall thermostat (DS01E Kit) if installed and bound. The
PTAC control will automatically self-configure to activate pre-configured energy management routine when the DD01E or
DD01F is installed and bound to the PTAC. Additionally, the setback times and setback temperatures can be changed using
the configuration settings. If you are using DP01* or DL01E Front Desk Platform, the PTAC control will need to be configured
to identify its room number placement.
Standard and DS01E Configuration
To enter configuration feature mode
Press and continue to hold the up and down
a two (2) second time frame. You will see " - - " displayed. Once you are in the configuration program, you can use
the HEAT button to move UP the various configuration settings or the COOL button to move DOWN the configuration
settings. The + or - keys will move up or down the selectable codes that you can change for each configuration
setting. Ensure that you are in the proper configuration setting before pressing the + or - key as you may accidentally
change a setting that you did not intent to change.
CENTER OF MAGNET
(IN HOLDER)
MUST BE 15/16" FROM THE
SENSOR MOUNTING PLATE
:
arrow keys and quickly press the OFF
9
DD01E
AIR CONDITIONING SENSOR
key twice within