Compact 120v ac power distribution panel 60a main breaker, with external rotary disconnect switch suitable for use as service equipment small cell, pico, micro, cran or macro. maximum 6 ul489 breaker positions with single spd. maximum 5 ul489 breaker posi
120v ac power distribution panel 60a main breaker with external rotary disconnect switch suitable for use as service equipment small cell, pico, micro, cran or macro (18 pages)
120v/208v/240v ac power distribution panel 60a - 125a main breaker suitable for use as service equipment small cell, pico, micro, cran or macro (14 pages)
Summary of Contents for Pts PTS90423 Series
Page 1
PTS90423 Series 120V AC Power Distribution Panel 60A Main Breaker, with External Rotary Disconnect Switch Suitable for Use as Service Equipment Small Cell, Pico, Micro, CRAN or Macro INSTALLATION GUIDE Compact 120V AC Power Distribution Load Center 60AMP Main Breaker with External Rotary Disconnect Switch...
Distribution Breakers ........................8 Optional Surge Protection Device…………………………………………………………….....8 2.4 Suitable for Use as Service Equipment............... .…….…..8 3.0 Inspecting and Unpacking of PTS90423 Series Panels ..............9 3.1 Steps to Inspect and Remove……………………………………………………………………….…9 4.0 Mounting............................9 4.1 Mounting Bracket..........................9 4.2 Mounting to Pole, Stanchion or Round Surfaces ................10...
AC Power Distribution Load Centers Installation Guide 1.0 Model Overview The PTS90423 Series of Small Cell AC Power Distribution Load Centers provides a custom factory fully assembled load center for Small Cell and CRAN deployments. The PTS90423 Series products are: Suitable for Use as Service Equipment.
Page 4
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide PTS90423 Outline Drawing Example with Dual SPD and 5 Load Positions Figure 2: Dimensional Drawings Caution: Installation shall be completed per all NEC and Local Codes. Do not install PTS90423 Systems before reading and understanding all specifications and installation guides provided.
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 1.1 Specifications Electrical Operating Voltage 120VAC Main Breaker 60Amp MAX Distribution Breakers Max of (6) UL489 Breakers 0-20Amp Power Input Wire Size #14 - #4 awg Cu - Al...
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 1.3 Wiring Diagrams PTS90423 Wiring Diagram Suitable for Use as Service Equipment NEUTRAL to GROUND BOND Require when using for SERVICE EQUIPMENT Drawing above shows equipped with Neutral to Ground Bond Required when Using for Service Equipment.
The PTS90423 is a compact AC Load Centers designed for Small Cell and CRAN Deployments where distribution of AC power is required. The PTS90423 Series of compact AC Load Centers can also be used for AC Power Distribution applications where limited space exists, excluding the ability to use a larger load center.
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 3.0 Inspecting and Unpacking of PTS90423 Series Load Centers 3.0.1 Inspect the packaging for obvious signs of rough handling and/or external damage. 3.0.2 Review Installation Guide. 3.0.3 Remove from plastic packaging.
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 4.2 Mounting enclosure to Pole, Stanchion or Round Surfaces 4.2.1 Customer is responsible to identify suitable location for mounting 4.2.2 Install Pole Straps and tighten per specifications -or - 4.2.3 Mark and drill anchors locations using template provided.
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 4.3 Mounting enclosure on flat surfaces 4.3.1 Customer is responsible to identify suitable location for mounting. 4.3.2 Mark and drill anchors or clips to secure enclosure to surface.
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 5.1 Removing Dead Front Access Plate 5.1.1 Locate Dead Front Access Plate set screw and remove 5.1.2 Set aside for reuse. 5.1.3 Review Equipment Ground Connection Points 5.1.4 Review Neutral Connection points 5.2 Wiring Ground Connections...
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 5.3 Wiring Service and Load Connections 5.3.1 Wiring to be done in accordance with NEC and Local Jurisdictions Code. 5.3.2 Wire the Service Ground to the internal ground bar 5.3.3...
Page 14
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide Figure 6: Standard Wiring Practice Example Caution: Installation shall be completed per all NEC and Local Codes. Do not install PTS90423 Systems before reading and understanding all specifications and installation guides provided.
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 5.4 Re-Intalling the Dead Front Access Plate 5.4.1 Reinstall the Dead Front Access Plate and ensure that it is seated correctly. 5.4.2 Reinstall the Dead Front Access Plate set screw and tighten.
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 5.5 Labeling the Breakers 5.5.1 If installed as Service Equipment, apply the "SERVICE DISCONNECT" label at the primary breaker positions If installed as Branch Equipment, apply the "MAIN DISCONNECT" label at the 5.5.2...
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 6.0 Installation Review Inspect the installation, verifying that all is in accordance with this document, NEC, and local Codes. Caution: Installation shall be completed per all NEC and Local Codes. Do not install PTS90423 Systems before reading and understanding all specifications and installation guides provided.
PTS 90423 Series Small Cell AC Power Distribution Load Centers Installation Guide 7.0 Document and Revision Control Author Tom Cooleen Date 06/05/2018 File Location www.pactechsol.com Revision Control Issue Number Date 09/05/2018 Description PTS90423 Series Installation Guide Prime Contact 1 Name...