Pts 9042 Series Installation Manual

Small cell ac power distribution load center

Advertisement

Quick Links

PTS 9042x Series
Small Cell AC Power Distribution Load Center
INSTALLATION GUIDE
SAP# 33364
T-Mobile
Compact Small Cell Power box
30AMP main, Single SPD (L-G), 4 x 7 AMP load breakers
No External AC Disconnect Switch
SAP# 33365
T-Mobile
Compact Small Cell Power box
30AMP main, Single SPD (L-G), 4 x 7 AMP load breakers
Integrated External AC Disconnect Switch
Scan the QR code above to link to current document or click the link below:
All Rights Reserved, 2017
PTS90420-3-7777##-P-0
PTS90422-3-7777##-P-8
http://www.pactechsol.com/TMOvendor
www.pactechsol.com/TMOVendor
888-820-3508
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9042 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Pts 9042 Series

  • Page 1 PTS 9042x Series Small Cell AC Power Distribution Load Center INSTALLATION GUIDE SAP# 33364 T-Mobile PTS90420-3-7777##-P-0 Compact Small Cell Power box 30AMP main, Single SPD (L-G), 4 x 7 AMP load breakers No External AC Disconnect Switch SAP# 33365 T-Mobile...
  • Page 2: Table Of Contents

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide Table of Contents 1.0 Model Overview ........................... 3 Figure 1: Dimensional Drawings....................5 1.1 Specifications ..........................7 Breaker Specifications……..……….…………………………………………………………………..8 1.3 Wiring Diagrams ........................9 1.4 Application……………………………………………………………………………………………….13 2.0 Features ............................13 Main Breakers ...........................
  • Page 3: Model Overview

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 1.0 Model Overview The PTS9042x Series of Small Cell AC Power Distribution Load Centers with optional External Disconnect Switch provides a custom factory fully assembled load center for Small Cell and CRAN deployments.
  • Page 4 PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide PTS90422 – Small Cell AC Power Distribution Load Center with External Disconnect All Rights Reserved, 2017 www.pactechsol.com/TMOVendor 888-820-3508...
  • Page 5 PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide Figure 1: Dimensional Drawings PTS90420 Outline Drawing Caution: Installation shall be completed per all NEC and Local Codes. Do not install PTS9042x Systems before reading and understanding all specifications and installation guides provided.
  • Page 6 PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide PTS90422 Outline Drawing Bottom view Caution: Installation shall be completed per all NEC and Local Codes. Do not install PTS9042x Systems before reading and understanding all specifications and installation guides provided.
  • Page 7: Specifications

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 1.1 Specifications Electrical Operating Voltage 120VAC Main Breaker 40Amp MAX Distribution Breakers Max of (6) UL489 Breakers 0-20Amp Power Input Wire Size #14 - #2 awg Cu - Al...
  • Page 8: Breaker Specifications

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 1.2 Breaker Specifications Breaker Specifications PTS P/N Description PT-KM1N-07A UL489A DIN rail Breaker, 07 AMP PT-KM1N-10A UL489A DIN rail Breaker, 10 AMP PT-KM1N-12A UL489A DIN rail Breaker, 12 AMP...
  • Page 9: Wiring Diagrams

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 1.3 Wiring Diagrams PTS90420 Wiring Diagram Caution: Installation shall be completed per all NEC and Local Codes. Do not install PTS9042x Systems before reading and understanding all specifications and installation guides provided.
  • Page 10 PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide PTS90420 Cabling Diagram Caution: Installation shall be completed per all NEC and Local Codes. Do not install PTS9042x Systems before reading and understanding all specifications and installation guides provided. Installation should be performed by a qualified installer.
  • Page 11 PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide PTS90422 Wiring Diagram Caution: Installation shall be completed per all NEC and Local Codes. Do not install PTS9042x Systems before reading and understanding all specifications and installation guides provided. Installation should be performed by a qualified installer.
  • Page 12 PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide PTS90422 Cabling Diagram Caution: Installation shall be completed per all NEC and Local Codes. Do not install PTS9042x Systems before reading and understanding all specifications and installation guides provided. Installation should be performed by a qualified installer.
  • Page 13: Application

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 1.4 Application The PTS90420 and PTS90422 are compact AC Load Centers designed for Small Cell and CRAN Deployments where distribution of AC power is required. The PTS9042x Series of compact AC Load Centers can also be used for AC Power Distribution applications where limited space exists, excluding the ability to use a larger load center.
  • Page 14: Inspecting And Unpacking Of Pts9042X Series Load Centers

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 3.0 Inspecting and Unpacking of PTS9042x Series Load Centers 3.0.1 Inspection 3.0.2 Inspect the packaging for obvious signs of rough handling and/or external damage. 3.0.3 Review Installation Guide.
  • Page 15: Mounting

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 4.0 Installation The PTS9042x Systems are certified for outdoor installations This section provides installations guidelines to insure the appropriate requirements are met. 4.1 Mounting Bracket 4.1.1 A mounting bracket is included and pre-installed with the enclosure and can be used as a template, or the mounting details below can be used, if preferred.
  • Page 16: Mounting To Pole, Stanchion Or Round Surfaces

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 4.2 Mounting enclosure to Pole, Stanchion or Round Surfaces 4.2.1 Customer is responsible to identify suitable location for mounting 4.2.2 Verify Customer Acceptable mounting requirements by type 4.2.3 Install Pole Straps and tighten per specifications -or - 4.2.4 Mark and drill anchors locations using Fig.
  • Page 17: Mounting To Flat Surfaces

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 4.3 Mounting enclosure on flat surfaces 4.3.1 Customer is responsible to identify suitable location for mounting. 4.3.2 Mark and drill anchors or clips to secure enclosure to surface.
  • Page 18: Removing Dead Front Access Plate

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 4.4 Removing Dead Front Access Plate 4.4.1 Locate Dead Front Access Plate set screw and remove 4.4.2 Set aside for reuse. 4.4.3 Review Equipment Ground Connection Points 4.4.4...
  • Page 19: Wiring Ground Connections

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 4.5 Wiring Ground Connections 4.5.1 Ensure enclosure is grounded as per NEC and Local Jurisdictions Code requirements. 4.5.2 Ensure that the neutral buss bar is grounded per NEC and Local Jurisdictions Code requirements.
  • Page 20: Wiring Service And Load Connections

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 4.6 Wiring Service and Load Connections 4.6.1 Wiring to be done in accordance with NEC and Local Jurisdictions Code. 4.6.2 Ensure connections are properly seated in set screw openings prior to tightening per specifications.
  • Page 21: Breaker And Modules

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 5.0 Main Breaker Replacement or Re-Configuration 5.0.1 Ensure Electrical Service feeding PTS9042X System is turned off and de-energized. 5.0.2 Verify Power is de-energized with test meter or DVM at input to Main Breaker 5.0.3...
  • Page 22 PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 5.0.12.2 If PTS90422, 5.0.12.2.1 Re-connect rotary switch wire back into the top of the main breaker 5.0.12.2.2 Ensure the wire is properly seated with the capture ring 5.0.12.2.3 Check and verify with an inspection mirror 5.0.12.2.4 Tighten set screw to breaker specifications...
  • Page 23: Load Breaker Replacement Or Re-Configuration

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 5.1 Load Breaker Replacement or Re-Configuration 5.1.1 Ensure Electrical Service feeding PTS9042X System is turned off and de-energized 5.1.2 Verify Power is de-energized with test meter or DVM at input to Main Breaker 5.1.3...
  • Page 24: Spd Replacement Or Re-Configuration

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 5.2 SPD Replacement or Re-Configuration 5.2.1 Ensure Electrical Service feeding PTS9042X System is turned off and de-energized. 5.2.2 Verify Power is de-energized with test meter or DVM at input to Main Breaker 5.2.3...
  • Page 25 PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 5.2.8 Pull top side of SPD away and off of the DIN rail, and remove SPD 5.2.9 Mark and place SPD on the side. 5.2.10 Check that the new SPD has set screw and capture ring fully open 5.2.11...
  • Page 26: Re-Installing Dead Front Access Plate

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 5.3 Re-Installing Dead Front Access Plate 5.3.1 Reinstall the Dead Front Access Plate and ensure that it is seated correctly. 5.3.2 Reinstall the Dead Front Access Plate set screw and tighten.
  • Page 27: Installation Review

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 6.0 Installation Review Inspect the installation, verifying that all is in accordance with this document, NEC, and local Codes. Caution: Installation shall be completed per all NEC and Local Codes. Do not install PTS9042x Systems before reading and understanding all specifications and installation guides provided.
  • Page 28: Document And Revision Control

    PTS 9042x Series Small Cell AC Power Distribution Load Centers Installation Guide 7.0 Document and Revision Control Author Tom Cooleen Date 12/08/2017 File Location www.pactechsol.com/TMOVendor Revision Control Issue Number Date 12/08/2017 Description PTS9042X Series Installation Guide T-Mobile Prime Contact 1...

This manual is also suitable for:

Pts90422Pts90420

Table of Contents