PERFORMANCE FEATURES

Solid State Full Wave Power Bridge -Uses generously rated power semiconductors for
Maximum reliability and long life.
Inner Current Loop Regulator - Inherent high bandwidth capability for fast response.
Semiconductor Fusing - Both AC lines fused for maximum protection in case of short
circuit.
AC Line Filter and Transient Voltage Suppressor Network - Eliminates interaction
between other drives or AC equipment.
Current Limit Ranges - Selectable current limit ranges to match the drive to the motor
being used. Provides smooth acceleration of high inertia loads.
Speed Regulator - 1 % accuracy armature voltage feedback with IR compensation or 0.5 %
accuracy with DC tachometer feedback. Regulation accuracy may be affected by the
tachometer selected.
Current (Torque) Regulator -
2% accuracy armature current regulator allows the user to control motor torque instead of
speed.
Circuit Board Indicators - Light emitting diodes (LEDs) on the control board indicate when
the drive is in Run Mode or the Current Limit is enabled.
Remote Current Limit - Available by the simple addition of a potentiometer.
Current Signal Follower lnput* - Allows the motor speed to be controlled by a current
signal from a commercially available transducer. The signal may be one of the following:
1 -5mA or 4-20mA
Voltage Signal Follower lnput* - Allows the motor speed to be controlled by a voltage
signal from a DC tachometer generator or a process voltage signal. It accepts an input with
a range of 0-200 Vdc.
Auto/Manual Operation - Standard circuitry allows the drive to be controlled by the
operator speed potentiometer or by the current/voltage signal inputs.
UL/cUL - All Focus 3 Drives are UL/cUL listed.
*Use voltage or current input
The current/voltage signal must be ungrounded and isolated from the AC power
source and other controls which use the signal. If the signal is not isolated, an
isolator (such as
One cannot make a connection to ground or a grounded device to any terminal or
connection point to the Focus 3 Non-Regenerative Drive without causing drive
damage. Such failures unfortunately cannot be warranted.