Manual de utilizare
Maintenance and
Functioning manual
Tecnologia 2 – Nave 7
08780 Palleja
Barcelona - Spain
 (34) 93 334 01 12
FAX (34) 93 440 25 64
comercial@ordisi.com
www.ordisi.com
Și întreținere

Advertisement

Table of Contents
loading

Summary of Contents for ORDISI ASPIT

  • Page 1 Manual de utilizare Și întreținere Maintenance and Functioning manual Tecnologia 2 – Nave 7 08780 Palleja Barcelona - Spain  (34) 93 334 01 12 FAX (34) 93 440 25 64 Mom-09 Edición 12 comercial@ordisi.com Fecha edición 2019/11/04 www.ordisi.com...
  • Page 2: Table Of Contents

    11.- TECHNICAL SPECIFICATION, EMC INFORMATION 1.- INTRODUCTION Your straightforward assurance on our products by purchasing an ORDISI, S.A. portable aspirator of the ASPIT series, is very much appreciated. Before to start the aspirator we recommend you to read carefully this manual. If you have any doubt, please contact with your provider, or directly with ORDISI, S.A.
  • Page 3: Installation And Commissioning

    4.- INSTALLATION AND COMMISSIONING 4.1.- UNPACKING Upon reception of the equipment, if package is seen as damaged, immediately check if device has been affected. If damages are confirmed, immediately refer them to sender. 4.2.- COMMISIONING Not to use in explosive atmospheres like the anesthetic produced ones by inflammable. Check room electrical installation where equipment is tobe fitted it such installation meets IEC (UNE) standards with a good earthing.
  • Page 4: Cleaning And Sterilizing

    / intrathoracic. • For a bibliography review, the described complications are: infection, haematomas, blood loss. ASPIT-G model has the same indications. The variation is that the inlet diameter of the plug is higher (8.5 mm) 5.- CLEANING AND STERILIZING 5.1.- BODY Before undertaking any operation, disconnect the equipment from electricity supply.
  • Page 5: Entertaiment And Maintenance

    Hydrophobic bacteria filter; Ref. FB-193, bag 10 units. 9.- DIAGRAMS AND DRAWINGS At the request of the customer, ORDISI, S.A. will be supply components lists, description of its, calibration instructions and whatever necessary information for to repair the equipment by qualified technical personnel.
  • Page 6 9.2 DIAGRAM ELECTRIC 9.3.- EXPLODED VIEW See page 12 & 13 10.- TROUBLESHOOTING FAILURE OR MALFUNCTION CAUSE SOLUTION Regulation control is open. Close control. Equipment starts up but doesn’t Suction tube wrongly inserted.. Insert correctly. aspirate. Cap improperly adjusted. Adjust properly. Equipment starts up but suction is not Bacterial filter is saturated.
  • Page 7 3 A/m 3 A/m should be measured in the intended installation location to assure VACCUM VARIATION IN RELATION TO ALTITUDE ABOVE SEA LEVEL, AT A TEMPERATURE OF 22ºC ASPIT Model Altitude above sea level Ph (mmhg) Ph (kPa) 500 m...
  • Page 8 ASPIT Pág. 8 de 9...
  • Page 9 ASPIT-G Pág. 9 de 9...