Section 4 Component Teardown
Door Sensing Switch, Primary Interlock
Switch And Monitor Switch Removal
1. Disconnect the power supply cord, remove oven
from wall, then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
NOTE
To discharge the high voltage capacitor, wait for 60
seconds and then short-circuit the connection of the
high-voltage capacitor (that is the connecting lead of
the high-voltage diode) against the chassis with the
use of an insulated screwdriver.
4. Remove the control assembly, referring to the
procedure of "Control Assembly And Power PCB
Removal".
5. Remove the two (2) screws holding the latch hook to
the oven cavity front flange.
6. Remove the latch hook from the oven cavity front
flange.
7. Disconnect the wire leads of each switch.
8. Remove each switch from the latch hook by pushing
the one (1) stopper tab holding each switch.
9. Now, each switch is free.
RE-INSTALL
1. Re-install each switch in its place. The primary
interlock switch is in the lower position, door sensing
switch is in the upper position and the monitor
switch is in the middle position.
2. Re-connect wire leads to each switch. Refer to
pictorial diagram.
3. Secure the latch hook (with two (2) mounting
screws) to oven cavity front flange.
4. Make sure that the monitor switch is operating
properly and check continuity of the monitor circuit.
Refer to Section 3.
4-9
Door Sensing Switch, Primary Interlock
Switch, And Monitor Switch Adjustment
1. Disconnect the power supply cord and remove outer
case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
NOTE
To discharge the high voltage capacitor, wait for 60
seconds and then short-circuit the connection of the
high-voltage capacitor (that is the connecting lead of
the high-voltage diode) against the chassis with the
use of an insulated screwdriver.
4. Remove the control assembly, referring to the
the procedure of "Control Assembly And Power PCB
Removal".
If door sensing switch, primary interlock switch and
monitor switch do not operate properly due to a
misadjustment, the following adjustment should be
made.
5. Loosen the two (2) screws holding latch hook to the
oven cavity front flange.
6. With door closed, adjust latch hook by moving it
back and forth, and up and down. In and out play
of the door allowed by the upper and lower position
of the latch hook should be less than 0.5mm. The
vertical position of latch hook should be adjusted so
that the door sensing switch and primary interlock
switch are activated with the door closed. The
horizontal position of the latch hook should be
adjusted so that the monitor switch is activated with
the door closed.
7. Secure the screws with washers firmly.
8. Check all of the switches operation. If any switch
has not activated with the door closed, loosen screw
and adjust the latch hook position.