Warning! This appliance is not suitable to be used by people (children included) with reduced physical or mental capabilities or with lack of experience and knowledge, otherwise they have been instructed by someone responsible of their safety. Children must be controlled in order they do not play with the appliance. DANGER - WARNING! The sealing bar may reach high temperatures during and after the usage process.
Page 3
The manufacturing company is therefore in no way responsible for the non-observance on the part of the user of the safety precautions listed in this handbook. CHAPTER 1 IDENTIFICATION “USER MANUAL” Regulatory references The instructions handbook is a document issued by the manufacturing company and is an integral part following definitions...
Machine manufacturer identification data and positioning of the “CE MARKING” plate. Identification of the manufacturing company as producer of the machine takes place in accordance with the legislation in force by means of the following documents: Declaration of conformity; (CE marking;) Instructions Handbook A special plate applied to the machine is marked permanently with the following data...
5. During the warranty period, for interventions modifications directly manufacturing under warranty, the replaced materials will not company. be charged, while the labour will be duly charged. During warranty period, interventions not included in the warranty for various reasons, both the materials replaced and the labour will be duly charged.
11. clean machine coating, panels and controls using soft and dry cloths, or cloths slightly soaked in mild alcohol or detergent solution. Obligations in the case of malfunction and/or potential danger Image 5.1. Pump oil level indicators Operators are obliged to signal any deficiency and/or potentially dangerous situation immediately to a direct superior..
Page 7
The earthing (yellow-green) must not be moved or disconnected. In the case of power 3P + N ie in the presence of the neutral wire (blue) must not be moved or dissected. Before cleaning the machine, disconnect the plug. CHAPTER 6 Image 6.1.
Page 8
2. The SOFT-VACUUM option allows the packaging Vacuum packaging of liquid or semiliquid of liquid products. products 3. All the vacuum packages can be stored in a refrigerated cabin. By means of the chamber vacuum packaging machines of our range it is possible to vacuum package liquid or semi-liquid products (soups, sauces, etc..) thus increasing their duration time and keeping hygiene and taste unaltered.
For the packaging of food with protective athmosphere, ensure to be using food certified gases, not explosive ones. CHAPTER 7 PUMP GASTRO: to activate the functions of vacuum in GN trays, pump cleaning and heating and manual sealing. OPERATION Vacuum gauge Printer (OPTION) Lighting button (indicating power electricity ON) 7.1_VACUUM CYCLE DESCRIPTION...
Page 10
Use + and – buttons to choose the desired language: English, Italian, Spanish, German and Vacuum time setting French. By pressing the button SET for some seconds in By pressing the SET button it is possible to each program, it will appear: confirm and pass to the following option.
Page 11
Gas flush setting By pressing again the SET button, there will be (GAS OPTION) an empty line on the display: By pressing again the SET button, it will appear: By using the keyboard, it is possible to insert a By using the buttons + and – it is possible to text of up to 16 lines to be printed on the increase or decrease the time of gas injection...
Furthermore, for an often usage of the machine, pump cleaning must be done every 6 months. CHAPTER 8 MAINTENANCE AND PRECAUTION The working of the machine and the pump must not be continued, as the pump is not suitable to be used continuously. Pump heating Internal components During winter time or with cold weather, it is...
Page 13
equipment supplied by the manufacturer company only. The check of pump, filters and electrovalves must be done every 2000 working hours by Image 8.2. Syilicon bar placed on the lid authorized personnel only. Funzionamento: Nelle macchine con orologio si alterna la scritta della 2.
Page 14
CHAPTER 9 PROBLEMS SOLVING ? AFTER SWITCHING ON, THE MACHINE DOES NOT START 1. Check that the plug is correctly inserted into the current outlet and in case check the contacts inside the plug itself. 2. Check that the micro-switch, positioned at the back under the left hinge , is correctly energized when the bell-lid is lowered.
Page 15
checking if the pointer of the vacuum gauge ? DO NOT LIFT THE LID ON OR RAISE A stays in place or if recedes. In the first case LITTLE we are diagnosing losses, so the problem is due to other source (vane pump, oil change, Verify the proper operation of the pistons cleaning pump).
Page 16
10.2_ LIST OF COMPONENTS OF THE EXPLODED VIEW Mod. machine Rif. exploded Description Quantity All models SWITCH O-I All models ADHESIVE LEXAN LCD1 All models ADHESIVE LEXAN LCD2 Mistral Ghibli ADHESIVE LEXAN LCD2 PRINT All models ADHESIVE LEXAN 7 SEGMENTS Auster Eos FRONT PANEL CONTROLS LCD1 Mistral Ghibli...
Auster Eos FRONT PANEL CONTROLS LCD2 Mistral Ghibli FRONT PANEL CONTROLS LCD2 Mistral Ghibli FRONT PANEL CONTROLS LCD2 PRINT Auster Eos FRONT PANEL CONTROLS 7 SEGMENTS Mistral Ghibli FRONT PANEL CONTROLS 7 SEGMENTS All models ELECTRONIC BOARD COMPLET LCD1 All models ELECTRONIC BOARD COMPLET LCD2 Mistral Ghibli ELECTRONIC BOARD COMPLET LCD2 PRINT...
Page 22
FREE STANDING CHAMBER 11.1_ EXPLODED VIEW 11.2_ COMPONENTS LIST OF THE EXPLODED VIEW...
Page 23
Rif. exploded view Mod. machine Description Quantity All Models SWITCH O-I 380V All Models ADHESIVE LEXAN LCD1 All Models ADHESIVE LEXAN LCD2 All Models ADHESIVE LEXAN LCD2 PRINT All Models ADHESIVE LEXAN 7 SEGMENTS All Models FRONT PANEL CONTROLS LCD1 All Models FRONT PANEL CONTROLS LCD2 All Models...
Page 24
11.4_ PRINTER + KEYBOARD DISPLAY BOARD: 11.5_ STANDARD ELECTRIC SCHEME:...
Page 25
11.6_ PRINT + KEYBOARD ELECTRIC SCHEME:...