ebm-paps K3G560-PB31-03 Operating Instructions Manual

Advertisement

Quick Links

K3G560-PB31-03
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 (0) 7938 81-0
Fax +49 (0) 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
CONTENTS
Item no. 55784-5-9970 · ENU · Change 202174 · Approved 2019-01-08 · Page 1 / 15
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
3
3
4
4
5
5
5
5
6

1.2 Staff qualifications

6
6
The device may only be transported, unpacked, installed, operated,
maintained and otherwise used by suitably qualified, trained and
6
authorized technical staff.
6
Only authorized specialists are permitted to install the device, to carry
7
out a test run and to perform work on the electrical installation.
8
8

1.3 Basic safety rules

9
10
The safety hazards associated with the device must be assessed again
11
following installation in the final product.
12
The locally applicable industrial safety regulations are always to be
12
observed when working on the device.
12
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
12
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
13
device without the approval of ebm-papst.
13

1.4 Voltage

14
; Check the device's electrical equipment at regular intervals; see
14
Chapter 6.4 Safety inspection.
14
14
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Advertisement

Table of Contents
loading

Summary of Contents for ebm-paps K3G560-PB31-03

  • Page 1: Table Of Contents

    Operating instructions K3G560-PB31-03 ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION Bachmühle 2 Read these operating instructions carefully before starting work on the D-74673 Mulfingen device. Observe the following warnings to prevent malfunctions or Phone +49 (0) 7938 81-0 danger to persons.
  • Page 2: Safety And Protective Features

    Operating instructions K3G560-PB31-03 WARNING 1.7 Mechanical movement Live terminals and connections even with device DANGER switched off Rotating device Electric shock Risk of injury to body parts coming into contact with the rotor or → Wait five minutes after disconnecting the voltage at all poles the impeller.
  • Page 3: Storage

    Operating instructions K3G560-PB31-03 1.11 Storage Conveying highly corrosive air, e.g. salt spray. Exception: devices ● designed for salt spray and correspondingly protected. ; Store the device, partially or fully assembled, in a dry place, Conveying air with high dust content, e.g. suctioning off sawdust.
  • Page 4: Technical Data

    Operating instructions K3G560-PB31-03 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Installed position: shaft horizontal (install support struts only vertically as illustrated) or rotor on bottom; rotor on top on request Cable diameter min. 4 mm, max. 10 mm, tightening torque 2 ± 0.3 Nm Tightening torque 1.5 ±...
  • Page 5: Nominal Data

    Operating instructions K3G560-PB31-03 3.2 Nominal data 3.4 Conformity to Radio Equipment Directive 2014/53/EU ebm-papst Mulfingen GmbH & Co. KG hereby declares that the radio Motor M3G150-IF equipment type «ARTIKELSTAMM Phase ARTNR» conforms to the directive 2014/53/EU. Technical data:- Frequency: 13.56 MHz...
  • Page 6: Mounting Data

    Operating instructions K3G560-PB31-03 Touch current <= 3.5 mA If several devices are connected in parallel on the supply side according to IEC so that the line current of the arrangement is in the range 16 - 75 60990 (measuring A, this arrangement conforms to IEC 61000-3-12, provided that circuit Fig.
  • Page 7: Electrical Connection

    Operating instructions K3G560-PB31-03 4.2 Electrical connection We recommend the use of 105 °C cables. Ensure that the minimum cable cross-section is at least DANGER AWG 26 / 0.13 mm². Voltage on the device Protective earth contact resistance according to EN 61800-5-1...
  • Page 8: Connection In Terminal Box

    Operating instructions K3G560-PB31-03 4.2.5 Leakage current ; Route the cable(s) (not included in the scope of delivery) into the terminal box. For asymmetrical power systems or if a phase fails, the ; Ensure separate routing of the supply cable(s) and the cables for leakage current can increase to a multiple of the nominal value.
  • Page 9: Connection Diagram

    Operating instructions K3G560-PB31-03 4.5 Connection diagram Conn. Designation Function/assignment CON1 L1, L2, L3 Power supply, phase, see nameplate for voltage range Protective earth CON2 RS485 interface for MODBUS, RSA; SELV CON2 RS485 interface for MODBUS, RSB; SELV CON2 Reference ground for control interface, SELV CON2 Function parameterizable (see “Optional interface functions”...
  • Page 10: Configuration Options

    Operating instructions K3G560-PB31-03 4.6 Configuration options Item no. 55784-5-9970 · ENU · Change 202174 · Approved 2019-01-08 · Page 10 / 15 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com...
  • Page 11: Equivalent Circuit Diagrams

    Operating instructions K3G560-PB31-03 4.7 Equivalent circuit diagrams Item no. 55784-5-9970 · ENU · Change 202174 · Approved 2019-01-08 · Page 11 / 15 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com...
  • Page 12: Checking Connections

    Operating instructions K3G560-PB31-03 4.8 Checking connections 4.10 Switching off the device ; Ensure isolation from supply (all phases). Switching off the device during operation: ; Make sure a restart is impossible ; Switch off the device via the control input.
  • Page 13: Maintenance, Malfunctions, Possible Causes And Remedies

    Operating instructions K3G560-PB31-03 6. MAINTENANCE, MALFUNCTIONS, POSSIBLE Ambient temperature Reduce the ambient too high temperature. Allow CAUSES AND REMEDIES the device to cool down. Do not perform any repairs on your device. Send the device to ebm- Impermissible Correct the operating papst for repair or replacement.
  • Page 14: Vibration Testing

    Operating instructions K3G560-PB31-03 Rotor Follow the Rotor Contact Visual inspection At least every Repair or position replacement position protection 6 months replacement of sensor instructions sensor cover for device calibration needs intactness or error calibration. damage Notify Device for Visual inspection At least every Replacement of ebm-papst.
  • Page 15 Operating instructions K3G560-PB31-03 WARNING Heavy parts of the product may drop off. Some of the product components are heavy. These components could drop off during disassembly. This can result in fatal or serious injury and material damage. → Secure components before unfastening to stop them falling.

Table of Contents