SETUP, ADJUSTMENTS AND CALIBRATIONS SERIES MODEL STXDF HYDRAULIC RIDE-ON TROWEL Revision #0 (11/05/18) To find the latest revision of this publication, visit our website at: www.multiquip.com PN: 13416...
MACHINE INFORMATION AND MAINTENANCE LOG Technician__________________________________e Date:___________________________ Machine Information MODEL LH Motor Serial No. Machine Serial No. RH Motor Serial No. Engine Serial No. Program ID Pump Serial No. Program Version Machine Setup and Calibration Information Hydraulic Pressure Settings Calibration Point 1/Left Point 2/Right (Hydraulic Oil Temperature Below 125 °F)
SAFETY INFORMATION Do not operate or service the equipment before reading Potential hazards associated with the operation of this the entire manual. Safety precautions should be followed equipment will be referenced with hazard symbols which at all times when operating this equipment. may appear throughout this manual in conjunction with Failure to read and understand the safety safety messages.
Page 5
SAFETY INFORMATION DECALS safety decals when they become diffi cult read. Manufacturer does not assume responsibility for any Decals associated with the operation of this equipment accident due to equipment modifi cations. Unauthorized are defi ned below. equipment modifi cation will void all warranties. GENERAL SAFETY ...
Page 6
SAFETY INFORMATION NEVER operate the equipment in an explosive atmosphere www.aem.org. or near combustible materials. An explosion or fi re could Order FORM PT-160 result causing severe bodily harm or even death. ENGINE SAFETY WARNING WARNING If applicable, NEVER use your hand to fi nd hydraulic leaks.
Page 7
SAFETY INFORMATION the engine or equipment can result if operating in speed ALWAYS keep the battery charged. If the battery is not ranges above the maximum allowable. charged, combustible gas will build up. DO NOT charge battery if frozen. Battery can explode. FUEL SAFETY When frozen, warm the battery to at least 61°F (16°C).
Page 8
SAFETY INFORMATION capacity and the lifting gear must be capable of lifting at Check the tire air pressure on both towing vehicle and least this amount. trailer. Check trailer information, or tire side wall for recommended tire pressure. Also check the tire tread ...
Page 9
SAFETY INFORMATION ENVIRONMENTAL SAFETY/DECOMMISSIONING EMISSIONS INFORMATION (DIESEL) NOTICE NOTICE Decommissioning is a controlled process used to safely The diesel engine used in this equipment has been retire a piece of equipment that is no longer serviceable. designed to reduce harmful levels of carbon monoxide If the equipment poses an unacceptable and unrepairable (CO), hydrocarbons (HC) and nitrogen oxides (NOx) safety risk due to wear or damage or is no longer cost...
TOOLS NEEDED The specialized tools listed in Table 1 are required to maintain and service the STX6DF ride-on trowel. Fleet technicians and servicing dealers must have these tools for efficient unit setup and component calibration. Table 1. Setup, Calibration, and Diagnostic Tools TOOL DESCRIPTION PART NO.
MACHINE INFORMATION 2. Pump Serial Number — located on sticker on pump NOTICE (Figure 3). Lower number is the serial number. The following machine information should be recorded on Machine Information and Maintenance Log for unit service tracking and for filing any warranty claims. MODEL 1.
GENERAL PROCEDURES 1. Remove plug (P/N: 42440) from J5 of main harness NOTICE (under the seat: above and left of the cup holder). These general procedures will be referenced in other 2. Install Setup Jumper (P/N: 42538 on J5). sections throughout the manual. REMOVE SETUP JUMPER (If installed).
Page 13
GENERAL PROCEDURES Table 2. Disable and Enable Options Open service tool. Setup Function DISABLE (Regardless Click “Machine Setup” button on main page. (This is the same functionality as of Setup Jumper) installing the Setup Jumper) Click button “Disable Setup Functions”. Setup Function Open service tool.
INITIAL CHECK AND ADJUSTMENTS HYDRAULIC OIL CHECK 4. The hydraulic oil reservoir cover will need to be removed in order to access the hydraulic oil fill cap. 1. Turn the ignition key to the ON position and press the Remove the five bolts securing the cover to the frame F3 button to access the machine information screen.
INITIAL CHECK AND ADJUSTMENTS ENGINE OIL 1. Open the back hood to access radiator. 2. Verify that the radiator drain cock is closed. 1. Pull the engine oil dipstick (Figure 9) out of its holder 3. Remove radiator cap. and wipe it with a clean rag. 4.
SERVICE TOOL SETUP AND CONNECTION WHITEMAN SERVICE TOOL (WST) INSTALLATION 5. Double-click on the 43053RevX.p1d icon on your desktop. One of the screens shown in Figure 13 will NOTICE appear. Click "Cancel". Make sure that the Sauer Danfoss Plus +1 Software is already installed before proceeding with the Whiteman Service Tool (WST) installation.
Page 17
Whiteman Service Tool Application SERVICE TOOL SETUP AND CONNECTION Whiteman Service Tool Application Connecting Laptop to Trowel 6. Click "Cancel" again when the new screen (Figure 14) 8. Click on "Tools". On the drop-down menu, click on comes up. "License Manager" (Figure 16). •...
LAPTOP CONFIGURATION CONNECTION PROCEDURE 4. When the CAN Gateway cable is connected to the laptop for the first time, it is necessary to install the NOTICE CAN driver software. The installation screen will appear (Figure 21). Click "Next" to install the software WST –...
LOADING SOFTWARE FILE DOWNLOAD PROCEDURE 6. Select file 43048_*.LHX file (* represents current revision of file) and click open (Figure 26). 1. Make sure laptop and machine are connected. See Connection Procedure section. 2. Turn key on machine to RUN position but DO NOT start machine.
LOADING SOFTWARE 9. Record program ID and version on Machine Information 3. Click "Download all parameter values" button. and Maintenance Log on the front of this manual. 4. After selecting "Download parameters to MCU", a new 10. Turn machine power off for at least 10 seconds prior dialog box will pop up (Figure 30).
MACHINE SETUP AND CALIBRATION CALIBRATE FOOT PEDAL c. Round % Sensor Voltage values to nearest percent and enter in DEPRESSED defaults for sensors 1. Turn key to ON position but DO NOT start machine. 1 and 2. 2. Click “CALIBRATION” button on machine setup page. d.
MACHINE SETUP AND CALIBRATION PITCH SENSOR CALIBRATION 9. Check that both left and right pitch neutral calibration points are at least 10.0 mm (Figure 37). 1. Make sure pitch actuator rod ends are screwed in far enough for the yoke to lift off the pressure plate when fully retracted.
INSPECTION FLUID LEVELS 4. Electrical (Cooling Fan) • Verify fan cycles on when key is turned on Record the following fluid levels on Machine Information and (will remain on for 10s). Maintenance Log in Inspection section. Refer to Fluid Fill and •...
FUSE INFORMATION Refer to Figure 38 for location on fuse panel. Table 3. Fuses Fuse Number Fuse Rating, Amps Connector Pin # Description RH Hyd Cooler Fan Open Open Left Lights Right Lights Accessory Power Port Left Pitch LH Hyd Cooler Fan Seat Switch Switches and Diagnostic Display Ignition Switched Power for Engine ECU, Fuse Box Signal and...
Page 26
SETUP, ADJUSTMENTS AND CALIBRATIONS HERE’S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING UNITED STATES Multiquip Corporate Offi ce MQ Parts Department 18910 Wilmington Ave. Tel. (800) 421-1244 (800) 427-1244 Fax: (800) 672-7877 Carson, CA 90746 Fax (310) 537-3927 (310) 537-3700 Contact : mq@multiquip.com...