MQ Multiquip J36E2 Operation And Parts Manual

Walk-behind trowel (2 hp electric motor)

Advertisement

Quick Links

OPERATION AND PARTS MANUAL
MODEL J36E2
WALK-BEHIND TROWEL
(2 HP ELECTRIC MOTOR)
S/N LE0118039 AND BELOW
Revision #2 (01/31/18)
To fi nd the latest revision of this
publication, visit our website at:
www.multiquip.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
PN: 23814

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the J36E2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MQ Multiquip J36E2

  • Page 1 OPERATION AND PARTS MANUAL MODEL J36E2 WALK-BEHIND TROWEL (2 HP ELECTRIC MOTOR) S/N LE0118039 AND BELOW Revision #2 (01/31/18) To fi nd the latest revision of this publication, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
  • Page 2 NOTICE Support is no longer available for J36E2 operation at 115 volts. If your J36E2 trowel is configured for 115-volt operation (S/N LE0118039 and below), it will need to be rewired for 230-volt operation. Please see the attached Safety Warning and Service Bulletin for details.
  • Page 3: Safety Warning

    From: Multiquip Product Department Subject: Only Operating J36E2/J42E on 230 VAC Dear Multiquip Customer, Our records indicate you purchased an MQ Whiteman power trowel equipped with a 2.0 hp electric motor rated for 115-volt or 230-volt operation. This type of trowel is identified by the following model numbers: J42E and J36E2.
  • Page 4: Warranty Information

    WARRANTY INFORMATION File your claim online via E-Warranty at http://service.multiquip.com/warranty-support.html or contact our warranty department for assistance at 800-421-1244. Campaign: Reference No. TR20190823 Labor Allowance: 1.0 hour total flat rate for rewire of unit from 115 VAC to 230 VAC. Your prompt attention to this matter is appreciated.
  • Page 5: Service Bulletin

    Product Group: Date Issued: Expiration Date: Service Bulletin No. 10/16/19 TR20190823 Trowels Bulletin Type Models/Series Affected: J36E2 _____ Mandatory S/N LE0118039 AND BELOW _____ Information Only J42E S/N ZD0158011 AND BELOW _____ Recommended Change Details Problem: We have learned that the electric switch that enables power interruption is underrated for the electrical current required for safe operation at 115 volts.
  • Page 6 WORK SAFELY! Only a qualified service technician with proper training should perform this procedure. Follow all shop safety rules while performing this procedure. REQUIRED TOOLS MAIN SWITCH BOX „ Flat-head screwdriver „ Phillips-head screwdriver „ Wire strippers/crimpers/cutters PREPARATION Place the trowel on secure, level ground in an area free of dirt and debris.
  • Page 7 4. Remove and discard the existing power cable and 3. Connect the three pigtail assembly wires inside the fitting (Figure 4). main switch box as shown in Figure 6. NEW PLUG INSTALLATION MAIN SWITCH BOX 1. Locate the 230V pigtail assembly (P/N 30718). Strip the insulation back 1/4"...
  • Page 8 CRIMP SPLICE CAP SLEEVE INSULATOR P/N 19687 P/N 19688 WHITE BLACK YELLOW/BLACK YELLOW WIRE NUT BROWN BLACK P/N 34938 ORANGE WHITE ELECTRIC MOTOR Figure 7. Motor Wiring MOTOR WIRING 1. Connect the black, orange, and white motor wires as 4. Use the remaining pre-insulated crimp 16-12 AWG shown in Figure 7 using a crimp sleeve (P/N 19687) wire nut (P/N 34938) to cap off the brown wire from the motor.
  • Page 9 NOTES ELECTRIC WALK-BEHIND TROWEL — SERVICE BULLETIN TR20190823 — REV. #1 (10/16/19) — PAGE 5...
  • Page 10: Here's How To Get Help

    Service Bulletin Electric Walk-Behind Trowel 230V Wiring Update HERE’S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING UNITED STATES Multiquip Inc. (310) 537- 3700 6141 Katella Avenue Suite 200 Cypress, CA 90630 E-MAIL: mq@multiquip.com WEBSITE: www.multiquip.com UNITED KINGDOM CANADA...