Maintenance - Abexo POLY Quick Start Manual

Automatic chain barrier
Table of Contents

Advertisement

Place the front cover [4] on both the columns and secure it with the 2 screws [7] near the ground. Attach the chain to the eyebolts that
protrude from the front covers and tighten it so that the chain at the centre of the passage is at a height X with respect to ground. Before
moving on placing the rear cover, make the electrical connections, as written in the following paragraph.
CABLE TYPES AND MINIMUM THICKNESS
Refer to the attached CONT-R15 control unit manual.
Optional accessories mounting
POLY-PLUS
POLY-RING

MAINTENANCE

the six-monthly periodic maintenance plan provides for:
- remove 230V power supply or batteries if present
- clean and grease the monorail guide and inner chain sprockets
- grease the tow chain
- check that the screws holding the column are well tightened
- check the electrical connections
- restore power supply
- check obstacle detection operation (encoder system)
- check the correct functioning of all the command and safety functions
- replace any worn parts
4
Upper module with neutral plate for housing of accessories and control panel
Safety ring for metallic chain
POLY PLUS
1. Upper module
2. Base
3. Column
Put the base [2] Poly Plus inside the column [3]. Align the
4 holes [B] on the base with the 4 holes [B] on the
column.
Fix the base to the column with the 4 M10 x 20 screws
and the given nuts. Tighten the screws rmly!
The upper module [1] has 2 M10 threaded holes [A] at its
bottom. Lean the module on the base. Be sure to align
the holes and then x it with the 2 given M10X20 screws.
POLY RING
Assemble the ring as you see
in the picture and x it to the
eyelet and to the last link of
the chain.

Advertisement

Table of Contents
loading

Table of Contents