Trane TR250 Service & Installation Manual page 18

Pool and spa/hot tub heaters
Hide thumbs Also See for TR250:
Table of Contents

Advertisement

18
Vent Pipe & Terminal Specifi cations for Positive-Pressure Indoor Vent Kits
Heater
Service Kit Part
Model
Number
TR250
UHXPOSHZ12501
TR250NA
UHXPOSHZ12502
TR400
UHXPOSHZ14001
TR400
UHXPOSHZ14002
* For Heatfab single-wall vent pipe section length, "x" should be: 1, 2, 4, 5, or 7, where 1=6 inches, 2=12 inches, 4=18 inches, 5=24 inches, and 7=36 inches.
** For Heatfab double-wall vent pipe section length, "x" should be: 06, 09, 12, 18, 24, or 36, indicating the length of the vent pipe section in inches.
† For DuraVent vent pipe section length, "x" should be: 6, 12, 18, 24, or 36, indicating the length of the vent pipe section in inches.
‡ For these horizontal terminals, the wall penetration is included from the vent manufacturer. On all others, it must be ordered separately.
Maximum
Nominal
Installation
Vent Pipe
Appliance Adapter
Altitude
Diameter
10,100 ft
6 inch
Included in UHX kit
Heatfab P/N 1501329001
2,000 ft
4 inch
DuraVent P/N 810003683
10,100 ft
8 inch
Included in UHX kit
Heatfab P/N 1501646501
2,000 ft
6 inch
DuraVent P/N 810003725
Table 9
Vent
Gas
Type
Single-
Wall
NAT &
LP
Double-
Wall
Single-
Wall
NAT
or
ONLY
Double-
Wall
Single-
Wall
NAT &
LP
Double-
Wall
Single-
Wall
NAT &
or
LP
Double-
Wall
Horizontal Vent
Vent Pipe
Terminal
Heatfab Saf-T Vent EZ Seal
Heatfab P/N
P/N 960x *
5690CI ‡"
Heatfab Saf-T Vent CI Plus
Heatfab P/N
P/N CCA06Lx **
CCE06WP ‡
Heatfab Saf-T Vent EZ Seal
Heatfab P/N
P/N 940x *
9414TERM
or
DuraVent FasNSeal P/N
DuraVent P/N
FSVLx04 †
Heatfab Saf-T Vent CI Plus
Heatfab P/N
P/N CCA04Lx **
9414TERM
or
DuraVent FasNSeal W2
DuraVent P/N
P/N W2-x04 †
Heatfab Saf-T Vent EZ Seal
Heatfab P/N
P/N 980x *
5890CI ‡
Heatfab Saf-T Vent CI Plus
Heatfab P/N
P/N CCA08Lx **
CCE08WP ‡
Heatfab Saf-T Vent EZ Seal
Heatfab P/N
P/N 960x *
9614TERM
or
DuraVent FasNSeal P/N
DuraVent P/N
FSVLx06 †"
Heatfab Saf-T Vent CI Plus
Heatfab P/N
P/N CCA06Lx **
9614TERM
or
DuraVent FasNSeal W2
DuraVent P/N
P/N W2-x06 †
Vertical Vent
Terminal
Heatfab P/N 5600CI
Heatfab P/N
CCA06RC
Heatfab P/N
5400CI or
or
DuraVent P/N
FSRC4
FSTT4
Heatfab P/N
CCA04RC
or
or
DuraVent P/N
FSTT4
W2-RC4
Heatfab P/N 5800CI
Heatfab P/N
CCA08RC
Heatfab P/N
5600CI or
or
DuraVent P/N
FSRC6
FSTT6
Heatfab P/N
CCA06RC
or
or
DuraVent P/N
FSTT6
W2-RC6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tr400Tr250naTr250lpTr400naTr400lp

Table of Contents