Monitor PFT Step
INTERNAL COMM
TESTFAIL
CTL MOT PWR ON FAIL
MON SOL PWR ON FAIL
HALL 1 FAIL
HALL 2 FAIL
HALL 3 FAIL
HALL 4 FAIL
HALL 5 FAIL
HALL 6 FAIL
CURR OFFSET FAIL
SVO TYPE FAIL
CERT DATA UNINSTALLED
STRAP MODE MISMATCH
Monitor Fault
GIA DIS FAULT
HOST DATA DIF
HOST DATA INV
SVO PWER INV
STRP CODE CHNG
MET STUCK SWTCH
MET STATUS DIF
____________________________________________________________________________
LMM for the Kodiak 100
190-02102-00 Rev.4
Table 4-24. PFT Faults
This can sometimes be the result of a failure on the
other board. Check faults on the other processor.
Check unit power and AP Disconnect power.
Check unit power and AP Disconnect power.
Check unit power and AP Disconnect power.
Check unit power and AP Disconnect power.
Check unit power and AP Disconnect power.
Check unit power and AP Disconnect power.
Check unit power and AP Disconnect power.
Check unit power and AP Disconnect power.
Check unit power and AP Disconnect power.
Check unit power and AP Disconnect power.
Upload the certification gain file to the Monitor Board.
Check the connector strap inputs to the unit.
Table 4-25. Normal Mode Faults
Check the AP Disconnect power to the unit.
Check the AHRS wiring to the system.
Check the AHRS wiring to the system.
Check unit power and AP Disconnect power.
Check the connector strap inputs to the unit.
Check the MET switch inputs into the system.
Check the MET switch inputs into the system.