Hide thumbs Also See for NXG-1820-EUR:

Advertisement

Quick Links

NXG-1820-EUR Touch Screen User Manual
Introduction
NXG-1820 is an intuitive graphical touch screen interface for
users of the xGen security system. It is offering simple fingertip
control, via its clear 3.5 in. touch screen with easy to
understand graphic icons.
Speaker
System
Away Arm
(2)
Status
(5)
Main Menu
(6)
Partition List (7)
System Status bar – this colour coded section will provide
1.
detailed information about your system.
Note:
System Status Bar is shown only in disarmed state.
Away – touch this button to arm the system in Away Mode.
2.
Stay – touch this button to arm the system in Stay Mode.
3.
Off – touch this button to disarm the system and to
4.
acknowledge fault messages.
Status – touch this button for detailed status on partitions,
5.
zones, and devices.
Menu – touch this button to access the menus.
6.
Partition List – touch this button to view partition details.
7.
SOS – touch this button to access emergency features
8.
and the installer information.
© 2021 Carrier
Navigating the NXG-1820E Touch Screen
Status and information typically appears in the top section of
the screen.
User functions display in the middle of the screen. Navigation
buttons
allow you to scroll up and down through the
currently selected item/menu. Left and right arrows
to the previous and next items. Some screens feature a "Go to"
button
allowing you to navigate directly to the item.
The bottom tool bar may display a back button
the previous screen, a home button
screen, or an OK button
Status Bar
(1)
Entering a PIN Code
System
Stay Arm
You will need a valid PIN code to access to various features
(3)
and system information.
System
After a period of inactivity, a screensaver will appear and it will
go into power save mode. Tap the screen to wake it up. A
Disarm
screen will appear requesting to enter your code. A valid PIN is
(4)
required to unlock the screen and access the system.
Emergency
(8)
Enter a valid user code followed by ENTER
codes can be between 4 and 8 digits in length. The default
master user PIN code is 1234.
If you make a mistake, press the Delete key
If the PIN code is invalid for the feature you are trying to
access you will be returned to the home screen.
Permissions are assigned to users and keypads to determine
what features a user can access and at what times. If you are
unable to access a feature, contact your installation company
or building manager.
1 / 8
move
to return to
to return to the home
to save the current settings.
. User PIN
.
P/N 230444 • REV J • ISS 16MAR21

Advertisement

Table of Contents
loading

Summary of Contents for CADDX NXG-1820-EUR

  • Page 1 NXG-1820-EUR Touch Screen User Manual Introduction Navigating the NXG-1820E Touch Screen NXG-1820 is an intuitive graphical touch screen interface for Status and information typically appears in the top section of users of the xGen security system. It is offering simple fingertip the screen.
  • Page 2 Touching the Stay Mode button again will cycle the system to System Status Instant Stay Mode if this feature is enabled by your installation The xGen will display colour coded system status messages company. on the top of the main screen. In Stay Mode –...
  • Page 3 Entry via a zone with the Entry/Exit option will trigger an instant Touch the Off or Off + button to disarm your system: alarm. Similar to Instant Stay Mode, Night Mode requires the system to be disarmed (from inside or remotely) before entering the protected partition.
  • Page 4 Touch the Off or Off + button to acknowledge the alarm The list and grid buttons to switch between a list view and a condition and disarm the partition(s): grid view: Display Partition List Lock Out on 3 Invalid Attempts If your system has multiple partitions, touch the Partition Status Overview button (shown below) on the main screen to display If an invalid PIN code is entered three times, the keypad will...
  • Page 5: Navigating The Main Menu

    History This menu gives you access to the xGen event log. The event log will show the most recent event. Touch the up arrow to see an earlier event. Touch the down arrow to see the next event. Each event is numbered. “1” represents the most recent event. Up to 1024 events are stored.
  • Page 6 This option is commonly used to bypass zones that you wish to Program User PIN Codes temporarily add to your “stay mode”. Whilst still offering Each user has a unique PIN code that allows them access to security on the remaining zones, bypassing zones lowers your various features of the system.
  • Page 7: Test Functions

    Zone Number, Zone Name Test Functions • In Alarm – This zone has triggered a system alarm Periodic testing of your security system is critical to ensure it condition. Leave the protected partition and contact your operates correctly and alarm messages are being sent in case security company to investigate.
  • Page 8: Specifications

    EN 50131-1 System requirements Note: There are no invalid code EN 50131-3 Control and indicating equipment combinations. NXG-1820-EUR: Security Grade 2, Environmental Dimensions (W × H × D) 82 x 125 x 18 mm class II Tested and certified by Telefication B.V.