9 Disassembly and assembly / 9.20 Fitting wall insert
7. Move the wall insert fully in and remove the guide studs. Fit the remaining threaded
studs. Observe tightening torque. Leave the top threaded hole (x) in the compressor cas-
ing empty.
8. Check that 23 threaded studs have been fitted.
9. Press the wall insert into the compressor casing using a hexagon nut (72004) and sleeve
(90191). Observe tightening torque. Remove nuts and sleeves.