7 Periodic maintenance work / 7.3 Cleaning the turbine during opera-
tion
7.3.6
Carrying out wet cleaning of the turbine
CAUTION
Inadmissible thermal stress and flooding of the turbine
Smaller amounts of water can lead to an inadequate cleaning result. Larger
amounts of water lead to inadmissible thermal stress on the turbine com-
ponents and can cause flooding of the turbine.
It is imperative that turbine cleaning parameters are observed.
u
CAUTION
Maximum temperature at turbine inlet during cleaning
During cleaning, the temperature at the turbine inlet will rise and may strain
the material significantly.
Make sure the maximum temperature at the turbine inlet is not exceeded
u
during cleaning.
Fig. 30: Carrying out wet cleaning of turbines
Fulfil prerequisites.
u
Ensure that the water supply (01) is guaranteed.
u
Open the stop valve (02) and set the water volume flow V
u
cleaning parameters).
Close the stop valve (02) after 10 minutes.
u
Wait for 10 minutes; do not change the load during this stabilisation phase.
u
If the cleaning result is unsatisfactory or there is water leakage, contact an ABB Turbochar-
ging Service Station.
Parameter for 1-nozzle cleaning
Product
Temperature be-
fore turbine before
cleaning [°C]
A150
350 ... 430
A155
350 ... 430
Table 15: Wet cleaning of turbines, parameters for 1-nozzle cleaning
1)
Corresponds to a water pressure p
before the cleaning nozzle
© Copyright 2021 ABB. All rights reserved.
Maximum temperature
before turbine during
cleaning [°C]
530
530
of 1.5 bar (overpressure compared to atmosphere)
WT
HZTL4032_EN
with a flowmeter (03) (see
W
Water volume flow
Injection time
3
1)
V
[dm
/min] 
W
14.0
19.0
Rev.Q
[min]
10
10
January 2021