Installing the compressor casing
Fitting the wall insert and the diffuser
Fig. 70: Fitting the wall insert and the diffuser
Product
A150
A155
Table 49: Tightening torque (79041)
1. Fit a new O-ring (77005).
2. Fit the swivel lifting eyes (S) to the wall insert (77000). Secure lifting gear to the swivel
lifting eye.
3. Install the wall insert (77000) into the compressor casing and, when doing so, pay atten-
tion to the positioning pin in the compressor casing.
4. Fit the diffuser (79000) with fixing discs (79040) and screws (79041). Observe the tight-
ening torque.
© Copyright 2021 ABB. All rights reserved.
Size
M6
M6
HZTL4032_EN
Tightening torque [Nm]
8
8