Sony SS-SCL3 Service Manual page 21

Table of Contents

Advertisement

Record Level Adjustment
Procedure:
INTRODUCTION
When set to the test mode performed in Tape Speed Adjust-
ment, when the tape is rewound after recording, the "REC memory
mode" which rewinds only the recorded portion and playback is
set.
This "REC memory mode" is convenient for performing this
adjustment. During recording, the input signal FUNCTION will au-
tomatically switch to VIDEO.
(After recording, press the m button without stopping will re-
turn to the position where recording was started.)
1. Press FUNCTION button to select VIDEO. (This step is not
necessary if the above test mode has already been set.)
2. Insert a tape into deck, press the TAPE REC PAUSE/START
button, and then press the Y button to start recording.
3. Mode: Record
VIDEO (AUDIO) IN (J101)
315Hz 50 mV (–23.8 dB)
AF OSC
600 Ω
attenuator
4. Mode: Playback
recorded
position
set
5. Confirm playback the signal recorded in step 2 become adjust-
ment level as follows.
If these levels do not adjustment level, adjust the RV301 (L-CH)
and RV351 (R-CH) on the MAIN board to repeat steps 3 and 4.
Adjustment level:
CN301 playback level: 47.2 to 53.0 mV (–24.3 to –23.3 dB)
Adjustment Location:
[MAIN BOARD]
IC301
RV351
Record Level (R ch)
blank tape
CS-123
set
level meter
main board
CN301
Pin 3 (L-ch)
Pin 1 (R-ch)
CN301
RV301
Record Level (L ch)
CD SECTION
Note :
1. CD Block is basically designed to operate without adjustment.
Therefore, check each item in order given.
2. Use LUV-P01 (4-999-032-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10MΩ impedance.
4. Clean the object lens by an applicator with neutral detergent
when the signal level is low than specified value with the fol-
lowing checks.
S-Curve Check
BD (CD) board
TP(FEO)
TP(DVC)
Procedure :
1. Connect an oscilloscope to TP (FEO).
2. Connect between TP (FEI) and TP (DVC) ( 1.65 V) by lead
wire.
3. Turn Power switch on.
4. Load a disc (LUV-P01) and actuate the focus search. (In conse-
quence of open and close the disc tray, actuate the focus search)
5. Confirm that the oscilloscope waveform (S-curve) is symmetri-
cal between A and B. And confirm peak to peak level within 2 ±
0.5 Vp-p.
S-curve waveform
6. After check, remove the lead wire connected in step 2.
Note : • Try to measure several times to make sure than the ratio
of A : B or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
BD (CD) board
TP(RFAC)
TP(DVC)
Procedure :
1. Connect an oscilloscope CH1 to TP (RFDC) and CH2 to TP
(RFAC).
2. Turn Power switch on.
3. Load a disc (LUV-P01) and playback.
4. Confirm that oscilloscope waveform is clear and check if RF
signal level is correct or not.
HCD-CL1/CL3
Oscilloscope
symmetry
A
within 2 ±0.5Vp-p
B
oscilloscope
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chc-cl3Hcd-cl1Hcd-cl3Chc-cl1Ss-scl1Ss-scl1b

Table of Contents