Download Print this page

Philips Viva Cafe HD7825/66 Service Manual page 2

Advertisement

DISASSEMBLY- AND RE-ASSEMBLY ADVISE
Before you start dismantling!
For your safety be sure the plug is disconnected
!
from the mains!
The product is designed for easy access to the internal
components.
Make sure that all accessories like tank, podholder, drip tray,
spout and collector have been removed.
To remove the back cover, follow below steps:
- Remove the two Torx screws (T15)
- Remove the valve outlet.
- Start at the upper side of the back cover, using a flat head
screwdriver to unhook the top of the back cover and gently
pull the back cover from the appliance so that a little chink
between back cover and brew chamber becomes visible.
- Again use the screwdriver to unhook the two "snap locks" at
each side of the back cover, and gently move the screwdriver
in the direction of the opposite side of the appliance, in
such a way that the lips of the snap locks are bent outwards
and unhook.
- If all snap locks are unhooked, it is possible to remove the
back cover. Gently pull the back cover upwards to release
the bottom part of the back cover from the housing.
Please note that the back cover is still connected to the
pump.
- For reassembly follow these steps backwards.
To remove the brew chamber lid cover, follow
below steps:
- Place a large screwdriver on the
positions (see picture 1) and
lift the cover over the snap
locks on both positions, use
appropriate force.
- The cover lid can now be lifted
up, but stays attached to the
brew head by the push rod, to
remove the complete cover
including lever and push rod
squeeze both legs of the push
rod strongly together
(see picture 2), so that the two
pins will unhook out of the
hinge position on the brew chamber.
- To remove lever from lid cover, take a screwdriver and bend
carefully the two lips/ribs in the lid cover outwards and
push the lever with force out of the hinge.
- To reassemble, follow steps backwards, without using a
screwdriver.
A
(see exploded view).
picture 1
picture 2
HD7825/60 /61 /66
To remove the brew chamber head assy, follow
below steps:
- Remove the back cover.
- Place the appliance in front of you in such a way that you
are facing the rear side of the appliance.
- First remove the boiler from the snap lock position of the
brew chamber.
- To remove the brew chamber,
use your both thumbs
(see picture 3) and push
strongly with a little distortion
(rotation) until the brew
chamber comes loose
(upwards).
- Reassemble follow above steps backwards.
To reach the components placed inside
the base (for example exchange the NTC
temperature sensor) follow below steps:
- First remove back cover, three-way valve and boiler.
- The brew chamber can be removed by unhooking the
two snap locks behind the boiler, pull the brew chamber
upwards to remove it from the housing.
- Remove both Torx T15 screws
- Unhook the two snap locks on the back side of the base
with a screwdriver (see base), the housing can now be
removed.
- To remove the rest of the housing unlock the last 4 snap
locks on the base and gently pull of the front cover.
- To reassemble follow above steps backwards.
OPTIONAL (accessories)
- No specific issues
picture 3
B
(see exploded view).
2-8

Advertisement

loading

This manual is also suitable for:

Viva cafe hd7825/60Viva cafe hd7825/61