Specifications - Fujitsu General ASHG09KMCDN Design & Technical Manual

Wall mounted type
Table of Contents

Advertisement

1. Specifications

Type
Model name
Power supply
Available voltage range
Capacity
Input power
Current
EER
COP
Sensible capacity
Power factor
Moisture removal
Maximum operating current *1
Airflow rate
Fan
Type × Q'ty
Motor output
Sound pressure level *2
Heat exchanger type
Enclosure
Dimensions
(H × W × D)
Weight
Connection pipe
Drain hose
Operation range
Remote controller type
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum current is maximum value when operated within the operation range.
• *2: Sound pressure level:
– Measured values in manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *3: Available on Google Play
store or on App Store
Rated
Btu/h
Cooling
Min.—Max.
Btu/h
Rated
Btu/h
Heating
Min.—Max.
Btu/h
Rated
Cooling
Min.—Max.
Rated
Heating
Min.—Max.
Cooling
Rated
Heating
Cooling
kW/kW
Heating
Cooling
Cooling
Heating
L/h (pints/h)
Cooling
Heating
HIGH
MED
Cooling
LOW
QUIET
m
HIGH
MED
Heating
LOW
QUIET
HIGH
MED
Cooling
LOW
QUIET
dB (A)
HIGH
MED
Heating
LOW
QUIET
Dimensions (H × W × D)
Fin pitch
Rows × Stages
Pipe type
Fin type
Material
Color
Net
Gross
Net
Gross
Liquid
Size
mm (in)
Gas
Method
Material
Tip diameter
Cooling
%RH
Heating
®
. WLAN adapter is also required. For details, refer to the setting manual.
ASHG09KMCDN
kW
2.50
8,500
kW
1.0—3.8
3,400—13,000
kW
3.20
10,900
kW
0.9—5.7
3,100—19,400
0.540
0.21—1.08
kW
0.720
0.18—2.35
2.5
A
3.3
4.63
4.44
kW
2.37
94
%
95
1.3 (2.3)
6.0
A
9.5
670
530
410
280
3
/h
750
620
510
290
W
40
36
30
20
42
38
33
22
mm
Main1: 2 × 10, Main2: 2 × 7, Sub:1 × 4
Approximate color of Munsell N 9.25/
mm
kg
mm
Ø 13.8 (I.D.), Ø 15.8 to Ø 16.7 (O.D.)
°C
°C
Wireless (Wired, Mobile app*3 [FGLair
- 2 -
Wall mounted
Inverter heat pump
ASHG12KMCDN
ASHG14KMCDN
230 V ~ 50 Hz
198—264 V
3.40
11,600
1.0—4.2
3,400—14,300
4,100—15,900
4.00
13,600
0.9—5.9
3,100—20,100
3,100—20,400
0.800
0.21—1.25
0.26—1.25
0.960
0.18—1.8
0.185—1.9
3.6
4.3
4.25
4.17
2.74
96
97
1.8 (3.2)
7.0
11.5
690
560
450
280
780
630
520
290
Crossflow fan × 1
27
42
37
32
20
43
39
35
22
Main1: 210 × 670 × 26.6
Main2: 112 × 670 × 20
Sub1: 84 × 670 × 13.3
Man1: 1.2, Main2: 1.1, Sub1:1.4
Copper tube
Aluminum
Polystyrene
White + Pearl white (painted)
270 × 834 × 215
277 × 914 × 332
10.0
13.0
Ø 6.35 (Ø 1/4)
Ø 9.52 (Ø 3/8)
Flare
PP+HDPE
18 to 32
80 or less
16 to 30
] [option])
4.20
14,300
1.2—4.65
5.40
18,400
0.9—6.4
1.100
1.400
4.9
6.2
3.82
3.86
3.26
97
98
2.1 (3.7)
8.5
16.0
770
600
450
280
820
650
520
340
43
40
33
20
44
40
35
24
1. Specifications

Advertisement

Table of Contents
loading

Table of Contents