Black & Decker BW13 Original Instructions Manual page 33

Table of Contents

Advertisement

Available languages

Available languages

SPECIFICATIONS
Power
Working Flow
Max water Flow
Pressure
Maximum Pressure
PSI
T° Input
Maximum Input Pressure
Repulsive Force of the Gun to
the Maximum Pressure
Motor Insulation
Motor Protection
Sound Level K=3 dB(A):
L
(EN 60704-1)
PA
L
(EN 60704-1)
WA
Unit Vibrations (K=1 m/s
Weight
Problem
Pump does not reach
working pressure
Pump pressure drops during
suddenly use
Motor "buzzes" but fails to
start
BW17
AR, B2C 220 V~ 50 Hz
1700W (1,7 kW)
5,3 l/min
7 l/min
9 MPa (90 bar)
13 MPa (130 bar)
1885
50 ºC
1 MPa
11,9 N
Class F
IPX5
78,8 dB(A)
93 dB(A)
)
‹2,5 m/s
2
6,7 kg
Possible Causes
Nozzle worn
Water filter fouled
Insufficient water supply
Air being sucked into system
Air in pump
Adjustable nozzle not positioned correctly
Thermostatic valve tripped
Water being sucked from an open
container from a height of more than
0.5 m.
Water being sucked from an external tank
Inlet water too hot
Nozzle clogged
Inlet filter (7) fouled
Power supply voltage too low
Voltage drop due use of extension cable
Appliance not used for a long period
of time
Problems with TSS device
B3 120 V~ 60 Hz
1600W (1,6 kW)
5 l/min
6,5 l/min
9 MPa (90 bar)
13 MPa (130 bar)
1885
50 ºC
1 MPa
11,2 N
Class F
IPX5
78,8 dB(A)
93 dB(A)
‹2,5 m/s
2
6,7 kg
ENGLISH • 33
B2 220 V~ 60 Hz
1700W (1,7 kW)
5,3 l/min
7 l/min
9 MPa (90 bar)
13 MPa (130 bar)
1885
50 ºC
1 MPa
11,9 N
Class F
IPX5
78,8 dB(A)
93 dB(A)
‹2,5 m/s
2
2
6,7 kg
Solution
Replace nozzle
Clean filter (7) (Fig. E)
Turn on water supply tap fully
Check tightness of hose fittings
Switch off the appliance and keep depressing
and releasing the gun trigger until the water
comes out in a steady flow. Switch the appliance
back on again.
Set nozzle (4) (+) setting (Fig. C)
Wait for correct water temperature to be
restored
Reduce the suction height.
Connect appliance to the mains water supply
Reduce temperature
Clean nozzle (Fig. E)
Clean filter (7) (Fig. E)
Check that the voltage of the mains power supply
line is the same as that on the plate (Fig. B)
Check characteristics of extension cable
Contact your nearest Authorised Service Centre
Contact your nearest Authorised Service Centre
BR 127 V~ 60 Hz
1600W (1,6 kW)
5 l/min
6,5 l/min
9 MPa (90 bar)
13 MPa (130 bar)
1885
50 ºC
1 MPa
11,2 N
Class F
IPX5
78,8 dB(A)
93 dB(A)
‹2,5 m/s
2
6,7 kg