Rinnai EX38DT Installation And Operation Manual page 18

Direct vent wall furnace
Hide thumbs Also See for EX38DT:
Table of Contents

Advertisement

3. Install the Sleeve.
Attach the sleeve to the inside wall using 3 screws arranging the flange so that the marking
"TOP" is at the top. The flange is offset 2° to allow the condensate drain to the outside.
Apply silicone sealing evenly around the perimeter of the outside sleeve to avoid water intrusion.
3 screws
Figure 14
4. Install the Terminal.
Check that the terminal seal is in place. For weatherboard walls, add the second seal next to the
terminal seal to compensate for weather board angle. Adjust the second seal to make sure "Top"
marking of the second seal is located at the top or "Ʌ" marking is aligned with "V" marking on the
terminal.
From the outside insert the terminal into the sleeve with the marking "TOP" at the top. The left
hand side locking tie should be marked "LEFT".
Top Terminal
seal
Figure 15
18
Sleeve should extend
3/16 - 3/8 in (5-10 mm)
Apply silicone
sealing evenly
around the entire
seal.
Put silicone sealing evenly around the perimeter without any
gaps between the terminal seal and rough wall surface.
EX38DT Installation and Operation Manual
Indoor
Locking tie
Outdoor
Apply silicone
sealing evenly
around the
perimeter.
(Ʌ)
(V)
Terminal

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rhfe-1006fta

Table of Contents