Manual for Installation, Operation, and Maintenance of
5 Stage Point of Use Reverse
Osmosis Drinking Water System
AAA-RO-50
AAA-RO-100
Document ID #: AAA-RO
www.appliedmembranes.com
(760) 727-3711
sales@ appliedmembranes.com
Revision: 05/02/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AAA-RO-50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AMI AAA-RO-50

  • Page 1 Manual for Installation, Operation, and Maintenance of 5 Stage Point of Use Reverse Osmosis Drinking Water System AAA-RO-50 AAA-RO-100 Document ID #: AAA-RO www.appliedmembranes.com (760) 727-3711 sales@ appliedmembranes.com Revision: 05/02/2022...
  • Page 2: About Your Ro Water Treatment System

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System About Your RO Water Treatment System Thank you for your purchase of the AMI home RO reverse osmosis water treatment system. This drinking water system has been designed for quick and simple installation and maintenance. By carefully reading this instruction manual and following the operational guidelines you will ensure a successful installation and reliable operation.
  • Page 3: Table Of Contents

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Table of Contents About Your RO Water Treatment System ......................1  5 Stages of Water Treatment ..........................1  System On/Off Valves ............................1  Conditions for Operation ........................... 3  Warnings ................................
  • Page 4: Conditions For Operation

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Conditions for Operation Source Water Supply Community/Private Non-Chlorinated or chlorinated as long as the carbon filters (standard) are in place and replaced every 6 months. Chlorine will damage membranes if not removed properly.
  • Page 5: System Flow Diagram

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System System Flow Diagram Water supply to the first housing Faucet Water supply to the second housing Clean Water Outlet Water supply to the third housing Pollutants Outlet Housing with the RO Membrane Water Supply to the 4-way valve from the elbow connector “OUT”...
  • Page 6: Preparing For Installation

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Preparing For Installation Components Included Open the box and remove all of the components. Inspect them to ensure nothing was damaged during shipping. If any part is cracked or broken, please immediately contact our Customer Support. Identify and get familiar with the components.
  • Page 7: Recommended Tool List

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System System Component Identification RO Unit Top Part Components Post Carbon (T33) Filter RO Membrane Filter Bottom Part Components Filter Housings Sediment Filter CTO Carbon Block Filters (2) 1.
  • Page 8: Check Location

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Determine Installation Location  Space: Make sure there is sufficient space under the counter for installation (an area of about 16”L x 6”W x 18”H for the system, 11”D x 18”H for tank). ...
  • Page 9: Prepare Tubing

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Prepare Tubing Make your cuts against a flat cutting surface with a razor Notice: blade, or use a handheld tube cutter. Any cuts to your Tubing must be perfectly straight. Improperly cut tubing can fail to lock into fittings and cause leaking.
  • Page 10: Step 1 - Drill A Hole Into The Sink For The Faucet

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Step 1 - Drill a Hole into the Sink for the Faucet There are several options which do not require drilling. Check to see if any of these Notice: are feasible before proceeding to drill.
  • Page 11: Step 2 - Faucet Installation

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Step 2 - Faucet Installation For this step, you will need:  Faucet assembly kit included with System  Blue Tubing, cut to the appropriate length ...
  • Page 12: Step 3 - Drain Saddle Installation

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Step 3 - Drain Saddle Installation Notice: Some states require the use of an air gap faucet. Check your local plumbing code to assure compliance. For this step you will need: o Masking tape or duct tape o Variable speed drill w/ ⅛”...
  • Page 13: Step 4 - System Feed Line Installation

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Step 4 – System Feed Line Installation For this step you will need:  ½” and ” open-end wrenches (or two adjustable wrenches)  Teflon Tape ...
  • Page 14: Step 5 - Installing The Ro Storage Tank

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Connect the Feed Line Tubing  Unscrew the nut from the ball valve. Slide the nut onto the tubing, threaded sides facing the end of the tubing. ...
  • Page 15: Additional Point Of Use Connection (Optional)

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Additional Point of Use Connection (Optional) Ensure that all tubing and fittings used for RO product water are poly material, and Notice: not copper. Due to RO product water being very pure, it can leach the minerals from copper tubing which will cause a metallic taste in the water or ice and cause the copper tubing to develop pinhole leaks over time.
  • Page 16: Turning The System On For The First Time

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Turning the System On for the First Time Make sure all water supply and drain line connections are secure and free from leaks. Slowly turn on the cold water supply valve. Then slowly turn the feed valve counterclockwise until fully open (the handle should be in line with the tubing as it enters the connection).
  • Page 17: Replacement Parts

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Replacement Parts Unopened filters can be stored for several years if kept in an airtight container to prevent them from absorbing air. Store in a cool, dry, dark place (avoid heat and moisture contamination). Sediment Pre-Filter, Carbon Pre-Filter, Replacement Filter Kits:...
  • Page 18: System Maintenance

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System System Maintenance Notice: If your RO system is connected to an icemaker or other equipment, you must turn off the connection to the equipment before performing any maintenance. Filter Replacement Instructions All pre and post-filters should be replaced every 3-6 months.
  • Page 19: Troubleshooting Chart

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Troubleshooting Chart Symptom Possible Cause Remedy No water in the storage Filter Cartridges have Replace filter cartridges as indicated in tank clogged. maintenance section. System Feed Valve and/or Ensure the cold water supply, feed valve, and Tank Valve Closed tank valve are in the fully open position.
  • Page 20: Ro Basics

    Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System RO BASICS This section provides basic concepts on how an RO system works, how it performs in relation to your house’s water condition. We hope this information helps keep your RO system running at top performance for years to come.
  • Page 21 Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Water Pressure – The Most Important Factor! RO systems run on water pressure. Therefore, your water pressure has the most direct effect on how well your RO will perform.
  • Page 22 Installation and Service Manual – Under-the-Counter Point of Use 5 Stage Reverse Osmosis System Feeding Multiple Outlets: Feeding the filtered water to multiple outlets is doable. The key is choosing the right RO model that fits your house’s water pressure level. This model should fill up the tank quickly and fully. A frequently full tank will then provide good delivery pressure to feed the multiple outlets in your house.
  • Page 23 Product Warranty  SELLER hereby warrants to CUSTOMER that the goods herein described will be free from any liens or encumbrances, that good title to said goods will be conveyed to CUSTOMER by sale of same. SELLER warrants materials of its own manufacture against defects in material and workmanship under normal conditions of usage and service as specified in this manual for one year from whichever of the following events occur first: ...
  • Page 24 Replacement Schedule Our recommended replacement schedule is for average feed water quality. For cleaner city water, a lower frequency schedule may be sufficient. For applications where the feed water is dirtier or has specific issues, more frequent change-outs may be required. Generally speaking, filters should be changed when there is a loss of performance and after any extended periods of non-use.

This manual is also suitable for:

Aaa-ro-100