1.0 Installation and Startup Guide
0
Install Environment
7
Where
The MT-600/8000 Series is designed for industrial. The temperature range of operating
Used
is from 32 to 113 °F (0 to 45 °C) , as majority of industrial environments. It may not
be suitable for using in certain outdoor applications. Please consult the factory for
advised usage in outdoor applications.
NEMA
The MT-600/8000 Series front bezel is NEMA 4 rated. When installed properly in a
Rating
NEMA 4 panel, the NEMA 4 rating of the panel will not be compromised. This means
that fluids will not enter the panel during wash downs.
Electrical
The MT-600/8000 Series has been tested to conform to European CE requirements.
Environment
This means that the circuitry is designed to resist the effects of electrical noise. This
does not guarantee noise immunity in severe cases. Proper wire routing and
grounding will insure proper operation.
Mechanical
Avoid installing units in environments where severe mechanical vibration or shocks
Environment
are present.
2.0 Installation Instructions
1
2.1 Mounting Instructions
4
2.1.1 Location Considerations
8
Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC
output modules, contactors, starters and relays, and any other source of electrical interference are located
away from the back of the unit.
Particular note should be taken to the position of variable speed drives and switching power supplies.
Their input and load cables should be screened to a central star earth point.
MT-8000 series
MT-8104iH
Installation Instruction
1

Advertisement

Table of Contents
loading

Summary of Contents for weintek MT-8104iH

  • Page 1 MT-8000 series MT-8104iH Installation Instruction 1.0 Installation and Startup Guide Install Environment Where The MT-600/8000 Series is designed for industrial. The temperature range of operating Used is from 32 to 113 °F (0 to 45 °C) , as majority of industrial environments. It may not be suitable for using in certain outdoor applications.
  • Page 2: Making A Nema-4 Mounting

    2.1.2 Making a NEMA-4 Mounting Panel The unit can be mounted into panels with a depth of 4”(105mm). It is recommended that Details the unit be mounted on the front panel of a steel enclosure, through an appropriate opening*. Allow a clearance of 1”(25mm) around the sides of the unit for mounting hardware.
  • Page 3: Grounding Requirements

    If wiring is to be exposed to lightning or surges, use appropriate surge suppression devices. Keep AC, high energy, and rapidly switching DC wiring separate from signal wires. Equip ungrounded DC supplies with a resistor and capacitor in parallel to earth ground.
  • Page 4: Communications Connections

    independent of the programmable controller, for starting and interrupting the cycle. If provision is required for changing programs while the equipment is in operation, consideration should be given to the use of locks or other means of assuring that only authorized personnel can make such changes. These recommendations are intended as safeguards against the failure of critical components and the effects of such failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation.
  • Page 5: Usb Host Port

    1. Using USB cable mini side plug to HMI and another side plug into PC. The PC will display “Found New Hardware Wizard” dialog. Select “Install from a list or specific location (Advanced)”. 2. Check “Include this location in the search”, and assign the path to install Weintek HMI i Series driver from C:\EB8000\usbdriver.
  • Page 6: Dip Switch

    2.3.6 Dip Switch Mode Touch Screen Calibrate mode OFF Hide MT8000 System Setting Bar Boot Loader mode Reserve Normal Touch Screen Calibrate and Reset Password mode: In this mode when you power on the MT8000 series, the screen will display a “+” sign upper-left of the screen.
  • Page 7: Specifications

    Weintek products include the isolated power supply are covered by a limited liability warranty from defects in material and workmanship. This warranty does not apply: (a) if, in the judgment of Weintek, the product fails due to damage from shipment, handling, storage, acciden (natural and man-mad) ;...
  • Page 8 4.0 Dimensions of MT-8104iH 43mm [1.69"] 286.2mm [11.27"] 7mm [0.28"] 257mm [10.12"] 259mm [10.20"] DIP SW RESET Cutout dimensions: FUSE MT-8104iH: FUSE5X20 259mm [10.20"] W x 201mm [7.91"] H COM1 [RS485 2/4W] COM3 [RS485] COM1 [RS232] COM3 [RS232] COM2 [RS232]...

This manual is also suitable for:

Mt-8000 series

Table of Contents