Inverter Power Supply (U); Temperature Thermistor - Panasonic NN-GD391S Service Manual

Table of Contents

Advertisement

NN-GD391S / NN-GD371M
7.5.

Inverter power supply (U)

DO NOT try to REPAIR H.V. Inverter power supply
(U).Replace complete H.V. Inverter(U) Unit.
WARNING: HIGH VOLTAGE
Test if failure codes H95, H97 or H98 appear when performing
the following procedure. It is recommended to use an AC line
input current ammeter for testing.
Test 1
1. With the oven unit's AC power supply cord is unplugged
from the wall outlet, unplug the 2 pin H.V. connector CN703
from the magnetron tube.
2. Place 1 liter of water load into oven cavity.
3. Plug in the oven's AC power supply cord into outlet.
4. Program DPC.
a. Press Clock button once.
b. Press Timer button once.
c. Press Start button once.
d. Press Micro Power button once.
5. Program oven at High power for 1 minute and press [Start]
button.
a. After approximately 23 seconds, oven stops operating.
b. During
oven
approximately 0.5 to 1A. If both a and b are OK,
proceed to test 2.
INPUT CURRENT
Unplug CN703
Test 2
Continued from Test 1
1. Unplug the oven's AC power supply cord from outlet.
2. Unplug 3 pin connector CN701. CN703 remains unplugged.
3. Plug in the oven's AC power supply cord into outlet.
4. Program DPC.
a. Press Clock button once.
b. Press Timer button once.
c. Press Start button once.
operation,
the
input
current
FAILURE CODE
0.5 to 1A
Oven stops in 23
seconds after started.
d. Press Micro Power button once.
5. Program oven at High power for 1 minute and press [Start]
button.
a. After approximately 3 seconds, oven stops operating.
b. During
oven
approximately 0.4A.
Unplug CN701
If both a and b check OK, the Inverter Power Supply (U) can be
determined to be OK.
7.6.

Temperature thermistor

The thermistor that is attached to the magnetron detects the
temperature of the magnetron and will stop magnetron
operation when overheating is detected. A normal thermistor´s
resistance is 35KΩ to 110KΩ for an ambient temperature range
of 10-30 degree C.
If the resistance reading is out of the range stated here, the
thermistor is detective and must be replaced.
It is also possible to display thermistor level by taking the
following steps.
1. Program the DPC into TEST MODE (Plug-in oven → press
Clock button once → press Timer button once → press
Start button once → press Micro Power button once).
2. Program oven at Standing Time for 1 minute and press
[Start] button.
3. Press Micro Power once, the thermistor level reading will
shown on the display.
The normal reading should be in the range of 16-230.
is
18
operation,
the
input
INPUT CURRENT
FAILURE CODE
0.4A
Oven stops in 3
seconds after started.
current
is

Advertisement

Table of Contents
loading

Table of Contents