Page 1
Extractor hood LI60LBC24 User manual and installation instructions Register your product on My Siemens and discover exclusive ser- vices and offers. siemens-home.bsh-group.com/welcome The future moving in. Siemens Home Appliances...
en Safety Do not use the appliance: Table of contents ¡ With an external timer. 1.3 Restriction on user group USER MANUAL This appliance may be used by children aged 8 or over and by people who have reduced Safety .............. 2 physical, sensory or mental abilities or inad- Avoiding material damage........
Safety en WARNING ‒ Risk of poisoning! WARNING ‒ Risk of fire! Risk of poisoning from flue gases being Fatty deposits in the grease filters may catch drawn back in. Room-air-dependent heat-pro- fire. ducing appliances (e.g. gas, oil, wood or coal- ▶ Never operate the appliance without a operated heaters, continuous flow heaters or grease filter.
en Avoiding material damage Incorrect repairs are dangerous. WARNING ‒ Risk of injury! ▶ Repairs to the appliance should only be Components inside the appliance may have carried out by trained specialist staff. sharp edges. ▶ Only use genuine spare parts when repair- ▶...
Operating modes en Switch off the lighting if it is no longer required. Put the cooking lid on. ¡ When the lighting is switched off, it does not con- ¡ The cooking vapours and condensation are re- sume any energy. duced. Clean or replace the filters at regular intervals.
en Cleaning and servicing 6.2 Switching off the appliance 6.4 Switching off the lighting Press . Press . ▶ ▶ 6.3 Switching on the lighting The lighting can be switched on and off independently of the ventilation system. Press . ▶ 7 ...
Troubleshooting en 7.4 Removing the grease filter 7.6 Cleaning grease filters in the dishwasher ATTENTION! Falling grease filters may damage the hob below. The grease filters filter the grease from the cooking va- Grip below the grease filter with one hand. ▶ pour. Regularly cleaned grease filters guarantee a high level of grease removal.
en Disposal 8.1 Malfunctions Fault Cause and troubleshooting The appliance is not The mains plug of the power cord is not plugged in. working. Connect the appliance to the power supply. ▶ The circuit breaker is faulty. Check the circuit breaker in the fuse box. ▶...
Installation instructions en 11 Installation instructions Observe this information when installing the appliance. 11.1 Scope of delivery After unpacking all parts, check for any damage in transit and completeness of the delivery. 11.2 Unit dimensions You will find the dimensions of the appliance here 11.3 Safety clearances Comply with the safety clearances for the appliance.
en Installation instructions Risk of poisoning from flue gases being 11.4 Secure installation drawn back in. Follow these safety instructions when in- ▶ If an extractor hood with an open-flued heat stalling the appliance. production source is installed, the power WARNING ‒ Risk of poisoning! supply for the extractor hood must be Risk of poisoning from flue gases being provided with a suitable safety switch.
Page 11
Installation instructions en The appliance may fall down if it has not been Incorrect installation is dangerous. properly fastened in place. ▶ Connect and operate the appliance only in ▶ All fastening components must be fixed accordance with the specifications on the firmly and securely in place.
Page 12
en Installation instructions 11.7 Instructions for the electrical 11.10 Installation connection Checking the unit In order to safely connect the appliance to the elec- Check whether the fitted unit is level and has suffi- trical system, follow these instructions. cient load-bearing capacity. The max. weight of the appliance is 6 kg. WARNING ‒ Risk of electric shock! Ensure that the fitted unit is heat-resistant up to It must always be possible to disconnect the appliance...
Page 13
Installation instructions en Screw the appliance onto the mounting brackets. To set the air flow, change the position of the ab- Align the appliance and the mounting brackets in sorber. the cabinet and tighten all of the screws. In order to increase the air flow, open the one-way Secure the exhaust pipe to the air pipe connector.
Page 14
en Installation instructions Removing the appliance To avoid causing damage, do not bend the grease filters. Disconnect the appliance from the power supply. Loosen the screw connection with the fitted unit. Loosen the exhaust pipe. Remove the appliance. Remove the grease filters. 11.11 Air flow diagrams You can find the air flow diagrams below.
Page 15
Installation instructions en 0.50 0.63 0.75 0.89 0.93 1.06 1.12 1.23 1.36 1.47 1.57 1.69 factor Basic ventilation – size diagram Real pressure in the ventilation duct = The A-measured sound pressure level at 10 m² sabin = The A-measured sound pressure level relative to 1 pW...
Page 16
en Installation instructions Forced ventilation – adjustment diagram Static pressure drop Cut-away rings Existing opening of the reducing disc Without reducing disc Airflow = The A-measured sound pressure level at 10 m² sabin = The A-measured sound pressure level relative to 1 pW K-factor 2.41 2.82...
Page 17
Installation instructions en Forced ventilation – size diagram Real pressure in the ventilation duct = The A-measured sound pressure level at 10 m² sabin = The A-measured sound pressure level relative to 1 pW...
Page 20