IDEAL EXRKIT06 Replacement

IDEAL EXRKIT06 Replacement

Exalt gas valve

Advertisement

Exalt
Gas Valve Replacement
Kit Part Number
EXRKIT06
Each Kit Includes:
• Gas Valve
• Gas Valve O-Rings
Recommended Tools:
• Adjustable Wrenches
• Phillips Head Screwdriver
• Calibrated Combustion Analyzer
WARNING
!
Indicates a potentially hazardous situation which,
if ignored, can result in serious injury or substan-
tial property damage.
WARNING
!
For your safety, turn off electrical power supply
at service panel and allow unit to cool before pro-
ceeding to avoid possible electrical shock and
scald hazard. Failure to do so can cause severe
personal injury or death.
2019-62 Exalt Gas Valve Replacement
Revised 1.6.2022
Description
Gas Valve Replacement
NOTICE
Indicates special instructions on installation, operation
or maintenance, which are important to equipment
but not related to personal injury hazards.
WARNING
!
Failure to follow instructions below can result in
severe personal injury or damage if ignored.
Instructions are for a qualified installer/ ser-
vice technician only.
Read all instructions before proceeding.
Follow instructions in proper order.
Model
All Exalt
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EXRKIT06 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IDEAL EXRKIT06

  • Page 1 Exalt Gas Valve Replacement Kit Part Number Description Model EXRKIT06 Gas Valve Replacement All Exalt Each Kit Includes: • Gas Valve • Gas Valve O-Rings Recommended Tools: • Adjustable Wrenches • Phillips Head Screwdriver • Calibrated Combustion Analyzer NOTICE WARNING...
  • Page 2 Exalt Gas Valve Replacement 1. Preliminary Instructions 1. Verify that the Gas Valve replacement kit is correct for the model of boiler. See table on page 1. 2. Carefully open and unpack the PARTS BOX from its shipping carton. 3. Carefully remove and check for any damage. NOTICE Do not proceed with installation and contact Idealright away if the gas valve is damaged in any way.
  • Page 3 Exalt Gas Valve Replacement 9. Install new O-Rings in the opening on both sides of and low input firing rates and the burner is operating at op- the new Gas valve as shown in Fig. 4. timum conditions. WARNING The combustion testing and adjustments must be per- formed by a qualified installer, service agency or the gas supplier.
  • Page 4 DHW call which will enable ideal Tech Support at 1.800.411.9999 the DHW circulator. 9. Reattach the front jacket panel and return the unit 5.
  • Page 5 Exalt Gas Valve Replacement Table 1: Recommended Combustion Settings Fig. 7: Throttle Screw Location...