Removing nozzle ring
If only the nozzle ring needs to be removed, this can be dismantled at the turbine end.
Leaking connection
Reusing the removed spiral-wound gasket (61050) will result in leaking con-
nections. Spiral-wound gaskets may only be used once.
CAUTION
Provide new spiral-wound gasket (61050).
Blocked areas on nozzle ring
If a nozzle ring is blocked in some areas or is covered by loose parts, we
would recommend appointing an ABB Turbocharging Service Station to in-
NOTICE
spect the turbine blades and carry out a crack inspection.
In order to access the fixing screws, and loop round and transport the gas inlet casing, the
insulation has to be removed as required.
Damaged cleaning pipes
When looping around, ensure that any cleaning pipes present are not
pressed or damaged.
CAUTION
Never secure the lifting gear to the cleaning pipes.