Installing Nozzle Ring - ABB HT574400 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-M axial
8
Disassembly and assembly
8.8

Installing nozzle ring

Figure 42: Installing nozzle ring 1
1. Secure retaining plate (90338) with screws (90339) and hook in guide rod (90336).
2. Using lifting gear, position nozzle ring (56001) on guide rod (90336). Do not take strain off
lifting gear yet.
3. Fit guide plate (90328) with nuts (61037).
4. Remove the lifting gear.
5. Position nozzle ring (56001) in gas outlet casing.