Troubleshooting - Samsung UA H4100AR Series Service Manual

Table of Contents

Advertisement

4. Troubleshooting

4-1. Troubleshooting
Check List for Initial operation
AC Power Cord connected to the TV and the wall receptacle.
-
Standby Power/IR Indicator LED is turned On.
-
If Power/IR Indicator is not on check 14p power cable is connected and for correct Standby Voltage from SMPS
-
to Main. Also check Jog Function Cable.
Power turned On with Jog Function or Remote.
-
Power on command from main Board to SMPS.
-
Power/IR Indicator Flashes.
-
Panel Back Lights are turned On.
-
If no Backlights, unplug AC Power Cord, unplug 14 pin connector to SMPS, plug in AC Power Cord, Back light
-
should come on. Check Main Board operation for error.
Power/IR Indicator goes off.
-
Picture or banner is displayed.
-
* If nothing is displayed , check the LVDS cable.
Main Ass'y
Main Board Assy (CN201)
9
A13V_PW
7
A13V_PW
5
A13V_PW
3
A13V_PW
1
GND
10P Cable
LVDS Cable
Speaker
10
UNDER_DRIVER
8
PWM_DIMMING_OUT
6
SW_POWER_TO_SMPS
4
GND
2
GND
Power Ass'y
8P Cable
Power Board Assy (CNM803)
1
A13V_PW
3
A13V_PW
5
A13V_PW
7
A13V_PW
9
GND
4. Troubleshooting
2
OD_UD
4
BLU_PWM
6
PWR_On/Off
8
GND
10
GND