d2itsu APD-10HK User Manual page 27

Local air conditioner
Table of Contents

Advertisement

Available languages

Available languages

Removing Collected Water
■ Drainage way as follows.
1. In Cool, Dry or Heat mode operating, the condensation water will be drained to
the chassis.
2. When the chassis is full with water, the buzzer will give out 8 sounds and "H8" is
displayed to remind user to discharge water:
● Move the unit to a suitable place for discharging water; do not tilt the unit and
keep it horizontal during moving;
● Take the drainage pipe from the clip and pull out the rubber plug on the
drainage pipe to discharge water;
● After full water protection is eliminated and the compressor has been stopped
for 3 minutes, the unit will resume operation.