SYNCHRONOUS
Two RS-232 communication ports, J30 and J31 on HMS-317 and J24 and J25 located on the HMS-318 backplane
(see
Figure
13), provide for optional OS and AUX management interfaces to be connected to the HiGain system.
Table 2
lists the pin connections for the OS communication port connector.
connections for the AUX communication port connector.
Figure 13. HMS OS and AUX Asynchronous Management Ports
The HMU-319 requires that DSR be asserted by the connected DCE in order to establish
communications on this port. The HMU-319 always asserts DTR on this port.
HMS-317 and HMS-318
M
P
ANAGEMENT
J31
HMS-317
J30
J25
HMS-318
J24
Table 2. J30/J24 - OS RS-232 PORT (DTE)
Pin No.
Signal
2
Transmit Data (TD)
3
Receive Data (RD)
6
Data Set Ready (DSR)
7
Ground (GND)
20
Data Terminal Ready (DTR)
July 15, 2002
ORTS
Table 3 on page 14
Direction
Out
In
In
Out
Overview
lists the pin