8. Device Detail
Click the connected device icon to enter the detailed interface of the device, display the
vacuum pump status, and control the vacuum pump.
Expected completion
time
Real-time vacuum
Vacuum status
Leakage level
Vacuum unit switch
Read historical data
(1) Graph: when the vacuum value drops below 60000micron, the real-time vacuum
graph will be displayed.
(2) Expected completion time: when the vacuum status is close to stable, the remaining
vacuuming time will be displayed including the holding time.
(3) Motor control: motor stop status displays "
running status displays"
(4) Vacuum Value: display the real-time vacuum value.
(5) Temperature status of oil and shell: According to the setting alarm temperature,
display the temperature status "high", "normal", and "low" .
(6) Extraction Status: vacuum status display,
(exceed the range of vacuum sensor).
", click to run the motor; the motor
", click to stop the motor.
(Rise),
-17-
Graph
Motor control button
Temperature status of
oil and shell
Edit device name
Set logging interval
Recording status
(Decrease),
(Stable), ––