Tester Configuration Options - Bourns 4030 User Manual

Surge protector test set
Table of Contents

Advertisement

Tester
Configuration
Options
Mounting
Configurations
- Wall Mount/
Frame Mount
Option
2.
DIN
Rail
1.
Although the 1000 V model (4030-01) can measure a low voltage
device, when your application requires a precise measurement with
a slow rise below 50 V, the 250 V model (4030-02) is recommended.
With the 1000 V model, the startup may be as high as 50 V almost
instantaneously; therefore, a dv/dt may no longer be within the
desired limit.
NOTE: The Wall Mount/Frame Mount option must be specified when
ordering or returning to the factory for case modification.
The Wall Mount/Frame Mount option is based on DIN 3 Rail
hardware. An 8.7 inch DIN Rail is included with this option.
Installing the DIN Rail to the wall securely before installing the
Model 4030-01.
1. Using an appropriate fastener (not included); mount the DIN
Rail to the wall.
2. Go in at an angle from the bottom (see arrow 1) and then push
the top portion (see arrow 2) until a click is heard.
Installing the DIN Rail to the frame:
3. Locate the tester away from other operating switches or buttons.
4. Secure the DIN Rail to the frame using a 10/32 screw and/or
nut (not included) or standard screw for your specific frame or
cabinet.
5. Go in at an angle from the bottom (see arrow 1) and then push
the top portion (see arrow 2) until a click is heard.
In the Wall Mount/Frame Mount configuration, the lid is open and
in the down position.
USER MANUAL