83
1
12/21/2001
1. Fan Cycling Switch
2. Moisture Indicator
Fig. 1, Receiver-Drier
5. Pull the filter out of the HVAC assembly.
6. Install a new filter in the HVAC assembly. Be
sure that the arrow on the filter is pointing toward
the evaporator. See
1
10/04/2001
1. Evaporator
Fig. 2, HVAC Assembly Filter
7. Remove the condensate seal from the evapora-
tor service cover and install a new condensate
seal on the cover.
83/2
2
3
4
f543878
3. Binary Switch
4. Receiver-Drier
Fig.
2.
2
2. Filter
8. Using capscrews, attach the evaporator service
cover to the HVAC assembly.
9. Connect the wiring harness to the evaporator
probe.
10. Attach the lower HVAC cover to the dash panel.
For instructions, see Group 60 of the Business
Class® M2 Workshop Manual.
11. Remove the chocks from the tires.
f543921
Heater and Air Conditioner
Business Class M2 Maintenance Manual, August 2015
Need help?