Enovation Controls MURPHY PowerCore MPC-20-R2 Operation Manual

Enovation Controls MURPHY PowerCore MPC-20-R2 Operation Manual

Engine controller
Table of Contents

Advertisement

Quick Links

Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version:
2.9.23042; BTL: 02.09.10015.00]
MPC-20-R2 Engine Controller
*Approved by CSA for non-hazardous locations (Group Safety Publication EIC 61010-1, Third Edition)
Products covered in this document comply with European Council electromagnetic compatibility directive
2014/30/EU and electrical safety directive 2014/35/EU.
PowerCore
Operations Manual
®
00-02-0996
2019-06-13
Section 40

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MURPHY PowerCore MPC-20-R2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enovation Controls MURPHY PowerCore MPC-20-R2

  • Page 1 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] ® PowerCore MPC-20-R2 Engine Controller Operations Manual *Approved by CSA for non-hazardous locations (Group Safety Publication EIC 61010-1, Third Edition) Products covered in this document comply with European Council electromagnetic compatibility directive 2014/30/EU and electrical safety directive 2014/35/EU.
  • Page 2 In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications and designs at any time. ENOVATION CONTROLS has made efforts to ensure the reliability of the MPC-20 and to recommend safe use practices in system applications. Please note that in any application, operation and controller failures can occur.
  • Page 3 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] The MPC-20 can be set as an Auto Start Controller. Please be cognizant at all times of hands and other objects that are in close proximity to the machine(s) being controlled as they may commence operation suddenly and without warning.
  • Page 4 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] - THIS PAGE INTENTIONALLY LEFT BLANK - Section 40 00-02-0996 2019-06-13 - iv -...
  • Page 5: Table Of Contents

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Table of Contents Introduction ..........................7 Murphy PowerCore 20 Revision 2 (MPC-20-R2) ............7 User Interface ......................9 Accessing the Menu ........................ 10 Main Menu ..........................10 Auto Start/Stop Functions Defined ..................
  • Page 6 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Additional Screens ..................... 21 Warning and Shut-Down Icons .................. 26 Icon Troubleshooting ....................28 Menu Glossary ......................... 28 System (Low Security) ....................28 Engine Settings (Low Security) .................. 30 Advanced Engine Settings (Low Security) ..............
  • Page 7: Introduction

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Introduction This document is designed to familiarize a user with the MPC-20-R2 and explain how to navigate the interface and modify the settings when installing/operating the controller. The Quick Set Up guide assists with establishing the different functions in the MPC-20-R2 for system setup.
  • Page 8 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] • Prestart Delay 1: (Auto Only or Auto/Manual) after a start condition has been accepted by the controller, this delay begins timing, and the prestart output turns on. When this delay expires, the output is turned off, and the auto sequence continues.
  • Page 9: User Interface

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] User Interface The keypad on the MPC-20-R2 is comprised of 11 tactile buttons. This section describes the functions of each button. The buttons have the following functions: •...
  • Page 10: Accessing The Menu

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Accessing the Menu The MPC-20-R2 has three menu security levels to restrict users from making changes after installation. The security levels are Low, Medium and High. One may consider these security levels as user, technician and OEM.
  • Page 11 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] System The controller System menu provides the operator with the ability to set the Date/Time, Units, Language, Brightness, Contrast, Service Reminders and several other system settings. Review System under the Menu Glossary section of this manual for a full list and definition of each setting.
  • Page 12 • Analog Out [0-5VDC] Dedicated for analog throttling NOTE: Although the functionality exists to set all analog and digital inputs to the same function, Enovation Controls strongly advises against this. (Main Menu, page 2) Application Configuration The Application Configuration menu is where an operator will set up the controller’s Auto Start Functions and Auto Throttle Methods, if the intended use is an auto start and/or auto throttling controller.
  • Page 13 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] • Pressure Transducer • Level Transducer • Flow Transducer • Local Throttle Input Center Pivot / Linear Irrigation The Center Pivot / Linear Irrigation application houses the auto start functions and auto throttle methods meant to be used on center pivot and linear movement irrigation applications.
  • Page 14: Auto Start/Stop Functions Defined

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] • Running Loaded • Pressure Transducer • Local Throttle Input Frost Protection The Frost Protection application houses the auto start functions and auto throttle methods meant to be used on frost protection systems.
  • Page 15: Two Contact Maintained Start/Stop (Commonly Known As Floats)

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] The operator must press the green start key to activate the auto start sequence. The red stop key will initiate the auto stop sequence in the controller. Two Contact Maintained Start/Stop (commonly known as Floats) The Two Contact Maintained Start occurs when both contacts are active for an auto start and both contacts are inactive for an auto stop (not momentarily).
  • Page 16: Setting Up For A Mechanical Engine

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Setting up for a Mechanical Engine 1. Access Menu/Engine Settings/Engine Type, and select Mechanical then press [Enter]. 2. Press down arrow to Engine Manufacturer, select which engine manufacturer the controller is/will be used then press [Enter].
  • Page 17: Adjusting Screen Contrast

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] 7. Ensure Address Claim is set to the CAN address that the TSC1 and Tier 4 regeneration is expected to be sent from to the engine ECU (this is often times designated by the manufacturer/distributor). 8.
  • Page 18: Setting Up To Auto Start On Pressure

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] 5. Assign the Function of Auto Start Momentary/Maintained to one of the Digital Inputs then press [Enter]. 6. Assign the Function of Auto Stop Momentary/Maintained to one of the Digital Inputs then press [Enter].
  • Page 19: Setting Up To Auto Start On Flow

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] 12. Set the range of the transducer on the high side then press [Enter]. (i.e., 0-10ft transducer would show 4mA at 0 ft. and 20mA at 10 ft.) 13.
  • Page 20: Setting Up To Stop The Engine From Utilizing The Countdown Timer

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] 3. Utilize the Up and Down arrows to select Temperature Transducer in the main application configuration menu. 4. Establish a Start and Stop Temperature, and press [Back] twice. 5.
  • Page 21: Screen Examples

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Screen Examples Additional Screens The main screen (shown above) displays actual and target RPM, Oil Pressure, Engine Temperature, Battery Voltage, Engine Hours, Engine State and Mode of Operation. Section 40 00-02-0996 2019-06-13...
  • Page 22 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] The first six-up screen (shown above) displays Oil Temperature, Fuel Level, % Load, Fuel Rate, Suction and Discharge to the operator. If alternate parameters are desired, these may be changed within the free MPC- 20-R2 Software Configuration tool.
  • Page 23 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] When selected to be shown, the screen above displays the Regeneration Control for Tier 4 engines. The setting to show this page is in the Tier 4 Menu within Engine Settings of the main menu. Use the Enter button to change from Auto to Inhibit.
  • Page 24 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] The screen above allows the operator to see what the analog input functions are set to without accessing the menu. The screen above allows the operator to see what the digital output functions are set to without accessing the menu and the active setting which informs the user of the output status.
  • Page 25 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] The screen above allows the operator to see what the digital input functions are set to without accessing the menu and the active setting which informs the user of the input status. When selected to be shown, the screen above provides a list of service reminders and the hours left until the internal alarm will display the services needed.
  • Page 26: Warning And Shut-Down Icons

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Warning and Shut-Down Icons The following icons/symbols can be displayed at the bottom of the MPC-20-R2 screen to designate warnings or shutdown situations that have occurred: Icon Description Displays when High Exhaust System Temperature (HEST) is active and exhaust...
  • Page 27 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] FPT (DEF Level – Operator Warning) – Warning DEF Level below 10% FPT (DEF Level – Mid Level Inducement) – 65% of torque reduction; 40% engine speed reduction ramped within 40 minutes FPT (DEF Level –...
  • Page 28: Icon Troubleshooting

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Displays when an active or unacknowledged warning fault exists. The icon will disappear if the fault is acknowledged and is no longer active. Displays when an active or unacknowledged shutdown fault exists. The icon will disappear if the fault is acknowledged and no longer active.
  • Page 29 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Brightness – (Medium Security): allows the backlight of the screen to be adjusted. Factory set to 90. Contrast – (Low Security): allows the contrast of the screen to be adjusted. Factory set to 160. Backlight Control –...
  • Page 30: Engine Settings (Low Security)

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Clear Active ECU Fault Codes – (High Security): allows the operator to clear all active faults from the engine ECU. This setting should only be used by a qualified engine technician. All engine manufacturers and models may not support this feature.
  • Page 31 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Engine Manufacturer (High Security): allows the selection of the specific engine manufacturer (i.e., Caterpillar (M-T4F), Cummins (M-T4F), John Deere (M-T4F), Deutz (M-T4F), Kohler KDI 1903, Kubota (M- T4i, Gaseous), JCB (T4F), Volvo (T3-T4F), FPT (T4F), Isuzu (M), PSI (EControls ECU), Scania (T3-T4F), FORD (EControls ECU), Perkins (M-T4F), Other, HATZ (M-T4F), GM (MEFI ECU), Yanmar (T4F).
  • Page 32: Advanced Engine Settings (Low Security)

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Warm Up Delay – (Low Security): allows the operator to set the desired warm-up time/delay for the engine. This is the length of time the engine will run at its warm-up speed during the warm-up state. Factory set to 3 minutes.
  • Page 33 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Auto Stop Delay – (Medium Security): auto stop condition must remain active throughout this delay for an auto stop to occur. If the auto stop condition is removed during this delay, the delay is reset to zero.
  • Page 34 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Post Crank Lockout 1 – (Medium Security): Factory set to Low Oil Pressure Post Crank Lockout 2 – (Medium Security): Factory set to High Engine Temperature Post Crank Lockout 3 –...
  • Page 35 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] LOP Shutdown/High Speed – (High Security): Low Oil Pressure (LOP) setting in which the controller will provide a shutdown if dropping below at high speed. Factory set to 30.00 psi. Low Oil Pressure Warning –...
  • Page 36 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] High Level Warning – (Medium Security): sounds a warning when the system level reaches the set high limit parameter for system level. Selection only shown when an analog input is selected to monitor System Level.
  • Page 37: Throttle Menu (Medium Security)

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Low Suction Pressure Warning – (Medium Security): sounds a warning when the suction pressure reaches the set low limit parameter for suction pressure. Selection only shown when an analog input is selected to monitor Suction Pressure.
  • Page 38: Input / Output Menu (Medium Security)

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Target RPM Step Size – (Medium Security): step size of the target RPM when increasing and decreasing. The actual rate of change is much higher when throttling in auto vs. manually with the push buttons. Factory set to 25 RPM.
  • Page 39 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Digital input 1. Factory set to Disabled Digital Input 2. Factory set to Auto Start Momentary/Maintained Digital Input 3. Factory set to Auto Stop Momentary/Maintained Digital Input 4.
  • Page 40 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Relay Control: (chosen for control of one of the relay outputs when function is active) Shutdown, Controlled, Restart: (chosen to allow the controller to shutdown through the normal sequence of operation including cooldown when function is active.
  • Page 41 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Datcon Engine Temperature VDO Engine Temperature Murphy Fuel Level – (ES2F) VDO Fuel Level Datcon Fuel Level Murphy Oil Temperature – (ES2T-250/300) Datcon Oil Temperature VDO Oil Temperature Murphy Discharge Pressure –...
  • Page 42 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Relay 3. Factory set to Common Alarm. Relay 4. Factory set to Not Used. Relay 5. Factory set to At Load (Clutch). Relay 6. Factory set to Prestart 1 Delay. DO1 (5V, 200mA).
  • Page 43: Application Configuration (Medium Security)

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Application Configuration (Medium Security) Application – (Medium Security): Factory set to Pump All Purpose Pump All Purpose – houses most all auto start functions and auto throttling methods of the controller. This application is the most versatile application thus requiring so many combinations of settings for the operator to choose.
  • Page 44 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Pressure Transducer (Pump All Purpose, Center Pivot/Linear Irrigation, Air Compressor, Hose Reel Irrigation) read Pressure Type in detail below under Pressure Transducer menu for understanding of setup.
  • Page 45 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] LINEAR AUTO THROTTLE (LEVEL) 1800 RPM 1700 RPM 1600 RPM 1500 RPM 1400 RPM 1300 RPM 1200 RPM 6.5' 5.5' 4.5' START/STOP LEVEL NOTE: In order for linear auto throttle to work correctly the auto start/stop function and auto throttle method need to be set to the same transducer type.
  • Page 46 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] by decreasing the RPM below the deadband and increasing the RPM above the deadband to maintain the desired level of Pressure. Factory set to Discharge. Line Fill 1 Speed –...
  • Page 47 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Deadband Flow – (Medium Security): extends above and below the maintain set point. No throttling occurs while the flow is in the deadband. Factory set to 0 gpm. Flow Type –...
  • Page 48: Start / Stop Timers (Low Security)

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] order to work correctly. When the Auto Throttle Method is selected to Level Transducer and the Level Type is set to (Fill), the controller throttles the engine by increasing the RPM below the deadband and decreasing the RPM above the deadband to maintain the desired level.
  • Page 49: Communication (High Security)

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Tuesday Wednesday Thursday Friday Saturday Daily Off* Start Time: format of HH:MM:SS Stop Day: Sunday Monday Tuesday Wednesday Thursday Friday Saturday Daily Off* Stop Time: format of HH:MM:SS Communication (High Security) PVA Gauge: this function will be used if utilizing PVA Gauges on the RS485 Communications Port.
  • Page 50: Passcodes (High Security)

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] CAN Parameter Map – (High Security): allows an operator to enable or disable the CAN Parameter Map. The CAN Parameter Map can be used in place of the Modbus map when using a CAN device to talk to the controller for starting, stopping and control functions via telematics or another CAN based system.
  • Page 51: Communications

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Communications This section covers the RS485 Modbus Registers and Proprietary CAN Parameter Map. MPC-20-R2 RS485 Modbus Registers NOTE: The registers labeled Read/Write will allow the operator to change values through the Modbus as a temporary modification.
  • Page 52 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] 1 = Underspeed SD (0 or 1) 2 = Overcrank SD (0 or 1) 3 = Low Oil Pressure SD (0 or 1) 4 = High Engine Temp SD (0 or 1) 5 = Low Fuel SD (0 or 1)
  • Page 53 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] 15 = Reserved Reserved 40011 Read Only Actual System Level (50.5 ft will read 505) Feet 40012 Read & Write Modbus Engine Start/Stop Auto Mode Only (Stop = 0, Start = 1) (0 or 1) 40013 Read &...
  • Page 54 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] 40204 Read Only Version.App.4 Numerals 40205 Read Only Version.Config.1 Numerals 40206 Read Only Version.Config.2 Numerals 40207 Read Only Version.Config.3 Numerals 40208 Read Only Reserved Reserved 40210 Read Only J1939.Engine Catalyst Tank Level...
  • Page 55 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] 40227 Read Only Service Reminder - Battery Life Hours 40228 Read Only Service Reminder - Battery Life Remaining Hours 40229 Read Only Service Reminder - Belt Life Hours 40230 Read Only...
  • Page 56 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] 14 = Battery Low Warn (0 or 1) 15 = Amber Lamp Status (0 or 1) 40244 Read Only Active Warning Status (Active Fault: Bit = 1, Inactive: Bit = 0) 0 = Pivot Alignment Warn (0 or 1) 1 = Reserved...
  • Page 57 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] FF92 2 Bytes Read & Write Maximum Engine Speed Setpont FF93 2 Bytes Read Only System Voltage (12.5 will read 125) 2 Bytes Read Only Actual Engine Oil Pressure 2 Bytes Read Only...
  • Page 58 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] FFA5 1 Byte Read & Write System Level Maintain Deadband Feet Setpoint - Auto FFA6 2 Bytes Read Only Actual Flow Rate Gal/Min FFA7 2 Bytes Read &...
  • Page 59 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Read Only Pivot Alignment Warn (0 or 1) FFAF 4 Bytes 16-49 Active Shutdown Status (Active Fault: Bit = 1, Inactive: Bit = 0) Read Only Overspeed SD (0 or 1) Read Only...
  • Page 60: Supplementary Information

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Service Reminder – Oil Filter Life 2 Bytes Read Only Hours Remaining Service Reminder – Oil Life FFB5 2 Bytes Read Only Hours Service Reminder – Oil Life Remaining 2 Bytes Read Only Hours...
  • Page 61: Pc Configuration Software

    PowerVision allows engineering the ability to deliver quicker software updates with the flexibility of a software developer’s environment. The addition of PowerVision gives Enovation Controls the ability to provide a free-of-charge basic PC configuration program (PowerVision for Controllers) to all customers for changing default parameters within the controller.
  • Page 62: Specifications

    Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] Specifications Interface: Display: ▪ Monochrome, Transflective, White Backlight LCD with Heater ▪ 3.8 in./ 96.52 mm, QVGA (320 x 240 pixels) ▪ Languages: English, Spanish, German, French, Italian (3) LEDs: green (mode), yellow (warning) and red (shutdown) Operator controls: ▪...
  • Page 63 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00] - THIS PAGE INTENTIONALLY LEFT BLANK - Section 40 00-02-0996 2019-06-13...
  • Page 64 Software Release: [App: 02.09.10039.00; Config: 2.9.20024; Built in PowerVision Configuration Studio Version: 2.9.23042; BTL: 02.09.10015.00]...

Table of Contents