Trouble Shooting
During DRY operation, there is no air
sent out or fan speed cant be changed.
In HEAT mode, the outdoor unit
generates water or steam.
In HEAT mode, the indoor fan still
keeps running even the unit operation
stops.
Before asking for after-service to an authorized service center, please check your air
conditioner for the following items
The system couldn't start
Is power on/off switched on?
Is the power supply line
normal?
ON
OFF
The power on/off switch is
not at position of "ON".
7
This occurs during removal of the frost
(in defrosting operation) on the radiator
of outdoor unit.
Defrost operation
After the unit stops, the indoor fan will
continue to run for a while to eliminate
residual heat.
Is current leakage breaker
triggered?
Power
failure?
Please do immediately
cut off power supply and
contact the authorized
service center.
Installation Procedure
After selecting the unit installation location, proceed the following steps:
1. Drill a hole in the wall and insert the connecting pipe and wire through a PVC wall-through tube
purchased locally. The wall hole shall be with a outward down slope of at least 1/100. (See
Figure 2)
2. Before drilling check that there is no pipe or reinforcing bar just behind the drilling position.
Drilling shall avoid at positions with electric wire or pipe.
3. Mount the unit on a strong and horizontal building roof. If the base is not firm, it will cause
noise, vibration or pipe broken and refrigerant leakage (see Figure 6).
4. Support the unit firmly.
5. Change the form of the connection pipe, connection
wire and drain pipe so that they can go
through the wall hole easily.
Figure showing installation dimensions: (unit:mm)
a
Type
R407C:Series 07-09
R22:Series 09
615
Series 12-14
770
1064
R407C:Series 18-24
R22:Series 18-21
1215
R22:Series 24
R22:Series 07
465
h
R22:Series 09-21
R407C:Series 07-24
Notes
1.For electrical heating unit, the air outlet not allowed directly connecting with canvas
etc. easy catching fire goods.
2.This series' indoor unit are all low static pressure(30 Pa external static pressure ).
3.An access port must be provided during installation of indoor unit for maintenance.
When installing the ceiling concealed type indoor unit, a specially designed return air
bellows shall be installed, as shown in Figure 3, Figure 4.
Figure 3
Installing building roof
*0.5m(0Pa)or*5m(30Pa)
Ceiling
Air outlet duct
Air supply
Fig 2
g
b
c
e
h
i
d
f
648
450
225
55
225
125
100
674
804
450
225
55
225
125
100
828
1099
450
225
55
225
125
100
1124
125
1249
450
225
55
225
100
1383
500
440
225
55
225
125
100
640
h
R22:Series 07
R22:Series 24
A
Unit
Return air bellows
Return air