Haier AD242AMNAA Instruction Manual page 6

Duct type air conditioner
Table of Contents

Advertisement

SAFETY PRECAUTION
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T3.15A /250VAC.
4. The wiring method should be in line with the local wiring standard.
5. The power cable and connecting cable are self-provided.
The power cable should beH07RN-F 5G 2.5mm
3N~, 50Hz)) or H07RN-F 3G 4.0mm
The connecting cable should beH05RN-F 6G 1.5mm
All the cables shall have got the European authentication certificate. During installa-
tion, when the connecting cables break off, it must be assured that the grouding wire is
the last one to be broken off.
6. The breaker of the air conditioner should be all-pole switch; and the distance between its
two contacts should be no less 3mm.
7. The indoor unit installation height is at least 2.5m.
Maximum:
D.B / W.B
Minimum:
D.B / W.B
Maximum:
D.B / W.B
Minimum:
D.B
Maximum:
D.B
Minimum:
D.B
Maximum:
D.B / W.B
Minimum:
D.B / W.B
D.B / W.B
2
(for 36,42 series, 28 series (380-400V,
2
(for 24,28,36 series (1PH, 220-230V~, 50Hz)) .
2
.
5
32
/ 23
18
/ 14
43
/ 26
15
27
15
24
/ 18
-7
/ -8