Remote Control And Malfunction Judgement - Haier AB182ACBDA Operation Manual

Cassette air conditioner
Table of Contents

Advertisement

REMOTE CONTROL
Remote Control:
There is a telecommunication interface for remote control on the control panel o
indoor unit. After the peripheral equipment have been installed in accordance
instruction manual of the selected remote control detector, the air conditioner will
computerized and controlled from a far-away place.
Note: Air conditioner has installed detector,in order to add group control function,Can
refer to Centralized Controller installation and operation manual.
Power Failure Resume (to be applied for a necessary situation):
After the power failure compensation is set, if power failure suddenly occurs while the
conditioner is working, it will resume the previous working state when the power is su
again.
Setting Method: When the remote controller is on (excluding timer mode and fan
the state of power failure compensation.
Cancel Method: Press the "Sleeping" button on the remote controller 10 times w
mode will be cancelled.
Notes: When a power failure suddenly occurs during the air conditioner is working
the power after the power failure compensation is set, if the air conditioner will not be u
for a long time, please cut off the power supply to prevent its operation from being re
after the power is supplied again, or press the "Switch On/Off" button after the p
comes again.
MALFUNCTION JUDGEMENT
When the air conditioner does not operate properly after you have checked the above men
items or when the following phenomenon is observed, stop the operation of the air condi
and contact your sales dealer.
The fuse or breaker often shuts down.
Water drops off during cooling operation.
There is a irregularity in operation or abnormal sound is audible.
When the CHECK lamp flickers, an irregularity has occurred in the air conditioner.
Malfunction
E0
judgement
The trouble of the
Content of defect
drainage system
Note:
This unit has a function of automatic restart system after recovering power stoppage. Please contact
the sales dealer if it is not required.
press the "Sleeping" button on the remote controller 10 times within 5
seconds, and after the buzzer rings 4 times, the air conditioner will enter
seconds, and after the buzzer rings 2 timer, the power failure compensation
E1
The trouble of the
room temp. sensor
E5
E2
The trouble of the
The trouble of the
pipe temp. sensor
overload current
13
E8
The trouble of the main control
board communication
wit