2. Spray pressure settings
High-pressure -
Low-pressure
- To alter angle and pressure of the water jet,
turn changeover nozzle (4)
180°.
15
°
High-pressure
40°
Low-pressure
3. Suction operation
- When drawing water from a lake or drum, you
must use a suction hose with
filter.
- For water up to
86°
F the suction height must
not exceed a maximum of 3.3 ft.
~
~
Cold-wat°' suction hose
J~~
;
1
-----
Filte<
~
t~l------
::;;:J
'----
- When sucking water at temperatures between
86°-140° F the Power Washer must be situ-
ated at the same height as the water level.
4.
Spraying cleaning agent
Plug the cleaning-agent hose into the clean-
ing-agent connection on the cleaner anc;J turn it
slightly
to
secure it.
- Drop cleaning-agent suction hose (6) into
cleaning-agent container.
- Position changeover nozzle (4) to
"CHEM".
- The cleaning-agent intake can be adjusted by
turning the cleaning-agent adjustment valve
(14).
Tabel I
Valve setting
1
2
3
4
Cleaning agent
in jet(%)
0.5-1.5 1.5-2.9 2.9-4.6 4.6-6
- Press trigger gun.
- Following completion of cleaning, suspend
cleaning-agent suction hose (6) in a container
filled with
"clean"
water and flush through sys-
tem.