Before Returning For Repairs; Specifications - Schumacher SC1324 Owner's Manual

Automatic battery charger
Hide thumbs Also See for SC1324:
Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
The red
LED is lit.

14. BEFORE RETURNING FOR REPAIRS

If these solutions do not eliminate the problem, or for more information
about troubleshooting, contact customer service for assistance:
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT SHIP
UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number
from Customer Service at Schumacher Electric Corporation.

15. SPECIFICATIONS

Input .................................120V AC @ 60Hz, 10A max. continuous, 48A max. intermittent
Output .......................... 12V DC, 2A/40A cont., 6A int. (60 sec. max. on, 120 sec.min. off)
POSSIBLE CAUSE
The battery voltage is still below
10V after 2 hours of charging.
(or)
In maintain mode, the output
current is more than 1.5A for
12 hours.
Desulfation was unsuccessful.
Lack of progress is detected and
battery voltage is below 14.2V.
The battery's initial voltage is
below 12.2V and the total input is
less than 1.5 Ah.
The battery voltage drops to
below 12.2V in Maintain Mode.
services@schumacherelectric.com
www.batterychargers.com
or call 1-800-621-5485
Monday-Friday 7:00
The battery may be defective.
Make sure there are no loads on
the battery. If there are, remove
them. If there are none, have the
battery checked or replaced.
The battery may be defective.
Have battery checked or replaced.
The battery may be overheated. If
so, allow the battery to cool. The
battery may be too large or have a
short circuit. Have battery checked
or replaced.
The battery capacity is too low,
or the battery is too old. Have it
checked or replaced.
The battery won't hold a charge.
May be caused by a drain on the
battery or the battery could be bad.
Make sure there are no loads on the
battery. If there are remove them.
If there are none, have the battery
checked or replaced.
to 5:00
CST
am
pm
200A int. (5 sec. max on, 180 sec. min. off)