CALIFORNIA PROPOSITION 65 WARNING Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.
Specifications Concrete Pump Specifications SP 500 Concrete Pumpkit 80/50 x 1000:150 Concrete Valve Long Rock Maximum Strokes/minute 32.5 Maximum Concrete Volume 45 cu. yd 35 cu. m C4.4 Tier 3 - Diesel Motor 80 hp 60 Kw C3.4 Tier 4 - Diesel Motor 74.5 hp...
Page 18
Specifications SP 750-15 Concrete Pumpkit 80/50 x 1000:150 Concrete Valve Long Rock Maximum Strokes/minute Maximum Concrete Volume 50 cu. yd 38 cu. m C4.4 Tier 3 - Diesel Motor 100 hp 75 Kw C3.4 Tier 4 - Diesel Motor 100 hp 75 Kw Electric Motor 100 hp...
Page 19
Specifications SP 750-18 Concrete Pumpkit 90/50 x 1000:180 Concrete Valve Long Rock Maximum Strokes/minute Maximum Concrete Volume 70 cu. yd 53.5 cu. m C4.4 Tier 3 - Diesel Motor 100 hp 75 Kw C3.4 Tier 4 - Diesel Motor 100 hp 75 Kw Electric Motor 100 hp...
Page 20
Specifications SP 1000 Concrete Pumpkit 90/50 x 1000:180 Concrete Valve Long Rock Maximum Strokes/minute Maximum Concrete Volume 70 cu. yd 53.5 cu. m Diesel Motor (C4.4 Tier 3) 139 hp 104 Kw Diesel Motor (C4.4 Tier 4) 137 hp 102 Kw Electric Motor 125 hp 93 Kw...
Page 21
Specifications SP 1000HP Concrete Pumpkit 90/50 x 1000:150 Concrete Valve HP Short Rock Valve Maximum Strokes/minute Maximum Concrete Volume 35 cu. yd 26.7 cu. m Diesel Motor (C4.4 Tier 3) 139 hp 104 Kw Diesel Motor (C4.4 Tier 4) 137 hp 102 Kw Electric Motor 125 hp...
Page 22
Specifications SP 1250 Concrete Pumpkit 80/55 x 1400:180 Concrete Valve Long Rock Maximum Strokes/minute Maximum Concrete Volume 95 cu. yd 73 cu. m Diesel Motor (C4.4 Tier 3) 173 hp 129 Kw Diesel Motor (C4.4 Tier 4) 173 hp 129 Kw Electric Motor 150 hp 112 Kw...
Specifications Optional Equipment For more information on optional equipment, see “Optional Equipment” on page 88 • Autogreaser - Rock Valve • Auxiliary Hydraulic Circuit • Water Pump - Hydraulic • Air Compressor • Aux Hydraulic Connection • Carbide Wear Parts •...
All persons working near the concrete pump must be able to recognize hazardous situations. They must know how to avoid these situations and how to re-act quickly and appropriately whenever hazardous situa- tions arise. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
This shared oil, called rocking oil, keeps the two cylinders moving. A third hydraulic cylin- der (the Rock Valve slewing cylinder) cycles the Rock Valve back and forth. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
This is not the case with twin-circuit ma- chines. Even with the engine shut-off, pressure could SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
To bypass the dump valve, press and hold the override button. Press to engage Turn clockwise to release Figure 1 Emergency stop button SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Figure 4 either from above (through the hop- Concrete pump forward/reverse handle per) or from below (through the outlet pipe or clean out door). Serious inju- ry can result. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Find the cause of the problem, and repair it Soft Switch Relief Valve before activating the circuit again. Figure 7 Example of a pressure relief valves SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
HMI panel. Reset Procedure The horn must be sounded to reset the machine after an emergency stop button is reset. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
I. Rear Outrigger B. Power Pack J. Ram Change Station C. Rear Control Station (SCT) K. Agitator Handvalve D. Hydraulic Tank E. Fuel Tanks L. Horn Button F. Hopper SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Overview Pumpkit Overview A. Material Cylinders B. Differential Cylinders C. Rams D. Water Box E. Control Valve (S1/S2/S3) F. Accumulator G. Rock Valve SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
D. Breather E. E-Stop Manifold F. Main System Filter G. Agitator Relief Valve Accumulator / Accumulator Manifold A. Pressure Relief Valve B. Manual Bleed Off Valve C. Accumulator SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
D. Stroke Limiter E. Tension Nut E. Gear Pumps F. Locking Pin F. Accumulator Manifold Fuel Tanks A. Breather B. Fuel Cap / Gauge C. Cross Over Hose SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Concrete pump faults are listed on the Pump Codes °C Screen. Reference the “Concrete Pump Error Codes” LOW FUEL on page 59 to cross reference the error codes. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
If enabled - Temperature is above alarm set point ENGINE FAULT Check Engine Codes screen RAM CHANGE MODE Disables the Operator Panel and Remote controls. Idle goes to minimum, strokes go to minimum. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Cable Remote SP_PLC_ver-01.24.00F Options SP_MMI_ver-01.21.00F LEFT E-STOP Pump Codes Screen Displays pump code faults. - Press to return to the Menu screen. Pump Codes CLASS USER SOURCE CAUSE SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
INPUTS / OUTPUTS Displays active functions on the Cable Remote VBBs: - Press to return to the Menu screen. 22362 VBBo: Cable Remote 22362 VBBr: 22387 Vref: Test SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Used to change the current language of the HMI screens - Use the to move the through the list of languages. - Press to return to the Menu Screen Language Language Select ENGLISH SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Press once to put the concrete pump in reverse. If the concrete pump is in forward, press and hold to change from pump forward to pump reverse. = Pump/Reverse = Inactive ACC1 ACC2 SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 52
OFF position and then back Lights to the START position. Press to turn on the lights. Press again to shut the lights off. = Lights / On = Lights / Off SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Press once to put the concrete pump in reverse. Press and hold to change from pump forward to pump reverse. ACC1 ACC2 ACC1 ACC2 = Pump/Reverse = Inactive SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 55
= Throttle (-) = Inactive (Push/Hold) Horn Press once or press and hold to sound the horn. = Horn / On = Horn / Off (Push/Hold) SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Pressing the button again or moving Forward Reverse Neutral the handle to the neutral position will stop the agitator. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 58
Stroke Limiter (-) button to continually ramp down the strokes per minute setting. The Stroke Limit- er Indicator Lights will flash or become solid depending upon the current output. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Water pump Pump Codes Compressor Stroke Limiter CLASS USER SOURCE CAUSE Oil Cooler Agitator on Grease lubrication Concrete vibrator Horn Work Light Error Cause Cause Description Break Short SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Operation Preparing for the Job ........63 Selecting the setup location ......67 Personal Protection ........63 Laying out the pipeline ........68 Pipeline and Clamps ........63 Machine Preparation ........68 Tools and Accessories ........63 Starting the Machine ........70 Tow Vehicle ............64 Checking the machine ........70 Tow Vehicle Pre-Check ........64 Shutting the Machine Down ......71 Lubricating Slurry ...........71...
• Water hose and nozzle Steel Toed Shoes • Clean-out rake • Working lamps for night work • An approved air blow-out cap • Hand tools • Hammer Figure 1 Protective clothing SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
40 40 packages to accomplish anti-foaming, DIESEL D IE DIES Minimum silt settling, anti-wear, etc. The mixing Fill Level of these different chemical additive packages may render them useless. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
8. Plug in the electrical connections for the trailer brake lights and hook up the breakaway switch cable (Figure 5). SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Shifting cargo can result in loss of Figure 7 control of the trailer, and can lead to Setting rear outriggers death or serious injury. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
• When using the Cable Remote, position the re- Figure 8 mote box and cable where they will be out of the Laying pipeline way. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 69
This is one of the few times when it is better to under-grease than to over-grease. Re-grease agitator bearings every 2 or 3 hours, as the pour allows. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
“Pumping the Job” on page 77 to continue. • Use the Throttle Up button (Figure 16) to increase engine RPM’s. Press and hold this button until the engine is at maximum RPM. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
These products usually come in sandwich sized plastic bags, and lubricate about 100 feet of 5 inch pipe per bag. Instructions for mixing vary by the different man- ufacturers. These products are less expensive than SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 72
Mix more slurry as needed for the length of the pipeline, as described Figure 14 above. Mixing Slurry In Barrel SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 73
If the first chute full is all rock, have the driver dump it off to the side and show you the next chute full. The second chute full will almost always SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
(clockwise) to decrease strokes or out (counter clockwise) to increase strokes. Always return the manual stroke limiter to maximum strokes (full counter clockwise out position) when electrical power is restored. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Power ON Power OFF 5. The Transmitter will confirm the download is Button Button complete by flashing LED#3 eight times. Figure 19 Connecting the wireless remote LED #3 SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 76
Transmitter it may look like the paring works but it does not. This is related to a safety precaution. Replace battery and repeat the par- ing procedure. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Even with Figure 21 the hopper full of concrete, some compressed air will be Wash system as it’s removed introduced into the delivery pipeline. When it reaches SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Always keep the hopper at least half full. If the concrete is getting stiff, add water to the hop- per while you are waiting. A word of warning regarding SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
If you encounter another blockage, relieve the pressure again by pumping in reverse for several strokes before finding the remaining blockages. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
The result could be a violent whip of the hose as the air is released. If water must be conserved, dump the hoses manually and rinse them with the water nozzle. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 81
Rock Valve and material cylinders. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 82
• Close the hopper cleanout door, and reattach the pull any material from the exposed material cylinder, the bungy cord, if used. Rock Valve, and the outlet pipe (Figure 25). SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
• Replace the waterbox cover. • Put the pump into forward or reverse for one or two strokes to force the clean water out the drain. • Close the drain. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
• Maximum water pressure 100 bar / 1450 psi. • Minimum permissible spraying distance 12”. If the high pressure washer used generates a high- er water pressure, the spraying distance must be in- creased accordingly. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
ISO VG 32. Be aware, however, that this oil cannot protect the components to as high a temperature as the standard oil shipped with your unit (ISO VG 46). SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 86
Do not waste time when cleaning a machine in these conditions. Be very careful of ice when pumping in cold conditions. Never stand on ice-coated pipes or other round objects. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Do not dispose of nickel cadmium or nickel metal hydride batteries in Figure 28 household or business trash. Connecting the Emergency Power Harness SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
To be safe, you should be- gin the adjustment procedure by turning the adjustment device to the lowest possible setting, and then bring the device back up to the proper setting. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
• Perform the needed service on the unit. • Remove the labels, and reinstall the key Store the label in the document holder for future use. Typical Hydraulic Pump Spline Figure 2 Hydraulic pump spline SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
On the other hand, the thinner the oil, the lower the temperature will have to be before it breaks down the lubricating film that protects your components. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
1 will make it through. Although we are not happy about the one particle that is allowed through, we do not use finer filtration because the SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
The filter could also split open and leak to the ground, draining the reservoir, and contaminating the environ- ment. Dirty Filter Indicator Inlet Outlet Filter Figure 3 Hydraulic Oil Filter SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
If the oil has turned milky quickly, such as from one day to the next, then simply replacing the oil will not solve your problem. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 99
Figure 6 Agitator Grease Points Inspect for Damage or Leaks Visually inspect the unit for damage or leaks each day. Repairs should be made before the unit is operated. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Keeper Bolt Tension Nut Tension Nut Cover Bolts Figure 12 Loosen bolts on Rock valve cover and shaft Keeper Bolt Figure 11 Adjusting the Rock Valve tension nut SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 102
Tighten the keeper bolt. Lubricate mechanical moving parts Lubricate mechanical moving parts with oil or a lubri- cant such as WD-40. This applies to pins, hinges, valve handles and other components. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Never point or aim the gun/wand at yourself or anyone else. Never put your hand, fingers or body directly in front of the spray nozzle. Do not spray directly at electronics or electrical components. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
6. Apply light grease around the gasket of the new filter, such as Lubriplate 105. 7. Tighten by hand, with the oil filter wrench, tighten another half turn. 8. Start the engine, and check for leaks. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
7. Remove the spacer coupling from the waterbox about 1.5 inches of travel, which will allow you to (Figure 20). remove the spacer coupling (dogbone). When in position, shut-off the engine. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 107
9. There is a groove in the ram flange that will line up with a groove in the cylinder flange. The M12 x 45 bolt with nut will drop into this groove and allow SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Again, you should tighten the nut only finger-tight. Figure 25 Figure 27 Install new ram Retract cylinder away from ram SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 109
Be careful not to go too far (Figure 29). Figure 29 Move cylinder to spacer coupling SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 111
9. Do not open the nitrogen bottle supply valve yet. Turn the regulator adjustment handle on the high-pressure regulator (Figure 35) counter clockwise to its minimum setting (closed). SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 112
Never let nitrogen out of the accumulator by Accumulator pressing the gas valve pin with a foreign object. accum closeup The high pressure may rupture the valve seal! Figure 36 Accumulator protection cap SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
4mm allen wrench then tighten the jam nut. This should raise pressure cut-off above the main relief valve pressure set- ting. Restart the engine and place the concrete SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
RPM to idle, open the soft switch quarter turn valve, and either proceed to other pressure set- 5/32” Allen Head tings or shutoff the engine. 9/16” Jam Nut Figure 41 Soft switch relief valve SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Accumulator pressure cut-off screw 3. Read the pressure on the accumulator gauge. It should read the proper accumulator system pres- sure. Figure 44 Install pressure gauge in agitator circuit SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 116
7. Return the agitator handle to the neutral position. 1. Stop the engine and follow “Lock Out - Tag Out procedure” on page 92. 2. Remove the pressure gauge and cap fitting from the agitator circuit. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
The torque specifications on the following pages refer to wrench size, bolt size and thread pitch. Above is an example showing what those numbers refer to. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
90 % by tension and torsion. a. DACROMET/GEOMET 500 means coated with Te on and silver colored. ** Octagonal Mast b. Conversion: 1 Nm = .738 ft-lb. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
90 % by tension and torsion. a. DACROMET/GEOMET 500 means coated with Te on and silver colored. ** Octagonal Mast b. Conversion: 1 Nm = .738 ft-lb. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
All pressure ratings listed refer to 5-inch (125mm) diameters in like-new condition. Other pressures would apply to other sizes. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
This chart does not apply to double-wall pipe. Double wall pipe can be checked by inspecting the inside of the pipe. If the insert is intact, the pipe is okay. If the insert is worn through, the pipe must be replaced. Contact your pipe supplier for the pressure capacity of your double-wall pipe. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
125 mm / 80 mm x 2000 mm 230mm x 2000 mm 2 x A7VO-107 pumpkit and hydraulic 2 x 66KW output chart explain.eps pumps is shown here. Slewing cylinder 80 / 45 x 185 SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 129
21). NUMBER OF STROKES (stroke / min.) SIDE OIL VOLUME (liter / min.) 15.5 NUMBER OF STROKES PISTON (stroke / min.) SIDE OIL VOLUME (liter / min.) SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 130
• Make two copies of the output chart so you don’t ruin your original. You need one chart for each pump tested. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 131
CONCRETE OUTPUT (cu yd / h) NUMBER OF STROKES (stroke / min.) SIDE OIL VOLUME (liter / min.) 15.5 NUMBER OF STROKES PISTON (stroke / min.) SIDE OIL VOLUME (liter / min.) SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 132
Total (read on meter) (for plotting) (read on meter) (for plotting) 0 bar 100 bar breakpoint breakpoint 150 or 200 bar 250 bar 300 bar Check output form-fill2 SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
6" 3000 2500 2000 1800 1500 1200 1000 Pumpkit Model: 120/80 x 1600:200 Proportional value of pipeline in feet Slump of fresh concrete in inches Power: 132 KW SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 135
• 40 ft of 5-in. rubber hose All of these criteria will be explained in detail as we go • 150 ft of 5-in. horizontal steel pipe through the individual quadrants. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
The power factor number (PF) replaces the TK number should have a PF of 61,750 or greater. on a truck-mounted unit. It is the Kw multiplied by a SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 138
Round down to 500 feet to make it easy to use the chart. NOTE: Proportional value of the 41 meter boom and deck pipe system is 260 feet. This value includes elbows, reducer, and tip hose. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 139
3000 2800 2600 2400 2200 2000 1800 1600 1400 1200 1000 800 600 400 200 P in PSI The engine is a little too small. The intersection of 100 SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
An operator who has been issued a certification card by the American Concrete Pumping Association. There are several classes of certification, each relat- ing to a different category of pump. For an operator to SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 142
In some locations, electricians are not required to be SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 143
The area around a working piece of equipment or point of discharge where dangers can be encountered because of the nature of the machinery or process in use. For safety reasons, do not allow unauthorized SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Page 144
(larger aggregates of the mix) form a wedge inside the pipe. Resistance to movement then becomes overpowering and the concrete stops. Increasing pressure to try to remove the wedge only results SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Rock Valve is moved by the oil stored in an accumulator. Unauthorized Without authority, without permission. Examples: Un- SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Short Instructions Preparation............153 Starting the Machine ........153 Checking the machine .........154 Shutting the Machine Down ......154 Controlling the Concrete Pump ....155 Stroke Limiter ..........155 Cable Remote..........155 Cable Remote Functions ......156 Radio Remote (Optional) ......156 Radio Remote Functions ......157 Emergency Procedures .......158 Emergency Override Button ......158 Loss of Radio/Cable remote ......158...
Horn button, to clear the E-Stops. • Use the Throttle Up button to increase engine RPM’s. Press and hold this button until the engine is at maximum RPM. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Wait to Disconnect symbol / Battery switch • If the machine is stroking properly, you can either shutdown the machine or begin pumping the job, see “Pumping the Job” on page 77 to continue. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
(clockwise) to decrease strokes or out (counter clockwise) to increase strokes. Always return the manual stroke limiter to maximum strokes (full counter clockwise out position) when electrical power is restored. SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...
Do not dispose of nickel cadmium or nickel metal hydride batteries in Figure 7 household or business trash. Connecting the Emergency Power Harness SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual...