Thermador VCIN36JP Installation Manual page 13

Hide thumbs Also See for VCIN36JP:
Table of Contents

Advertisement

Available languages

Available languages

Blower Extension Cable Connection
The internal blower harness should be routed through the
knockout and secured with a 1'' (25.4 mm) strain relief. The
remote harness can then be connected to the blower
harness outside the unit.
Connects to
Remote or
Inline blower
A
Wiring the Hood with an
Integral Blower
7/ 8
6
1/ 8
4
"
(175)
(105)
Figure 9: Integral Blower Model VTN1030
Integral Blower models VTN630 and VTN1030 are
integrated into the hood at the time of installation (VCIN
models). For complete installation instructions see the
instructions supplied with the blower unit.
1. Remove junction box channel covering the wires (see
Figure 7 on page 10).
2. Remove circular knockouts (Figure 7 on page 10).
3. Connect the blower's Molex plug connector to the
connector present inside the hood, as shown in
Connects to
VCIxxJP hood
25ft cable
B
Figure 8: 25ft Cable
1/ 4
8
" (210)
7/ 8
8
"
(225)
1/ 4
2
"
(57)
3/ 4
6
"
(171)
"
25"
(635)
Figure 10.
From Control Panel
Figure 10: Wiring the Hood with an Integral Blower
4. Install 1'' (25.4 mm) conduit connector in junction box.
5. Run black, white, and green wires (#12 AWG) in 1''
(25.4 mm) conduit from the power supply to the
junction box.
6. Connect the power supply wires to the hood wires in
the following order: black to black, white to white, and
green wire to green ground screw on chassis. Use
spring type wire nuts.
Spring type wire nuts rated for a minimum of two
(2) #18 gauge wires and maximum of four (4) #14
gauge wires, UL & CSA rated to 600V and 302°F
(150°C.)
7. Close the junction box cover.
From Blower