2-2
Planning Repeater Installation
Electrical Requirements
The electrical requirements for a repeater are as follows:
NOTE: The repeater comes with a shielded AC power cord. If you lose or damage
the supplied shielded power cord, replace it with a shielded power cord that meets
local regulatory requirements to ensure emissions compliance.
Spatial Requirements
The repeater's dimensions (HxWxD) are 1.75 x 17.00 x 13.65 inches (4.5 x 43.6
x 35 cm).
You can interconnect up to five repeaters in one stack. Be sure to allow at least
2 inches (5.1 centimeters) on each side of the repeater for proper air circulation
and cable connections.
Cable Requirements
This section defines the requirements for cable used to connect the RJ-45 ports,
the Smart Uplink port, and the serial COM port on repeater.
Voltage: 100 to 240 VAC
Power: 1.5 (@ 100 VAC) to 0.90A (@ 240 VAC)
Frequency: 50 to 60 Hz
CAUTION:
The power outlet must be a non-switched, grounded power
source. Do not use a three-to-two pronged adapter at an outlet. Doing so
may result in electrical shock and/or damage to the repeater and will void
your warranty.