Summary of Contents for oventrop Regumaq X-80

  • Page 1 Regumaq X-80 Potable water circulation set Operating instructions...
  • Page 2: Table Of Contents

    Regumaq X-80 Potable water circulation set Contents Page General information ......................3 Validity of the instruction ........................3 Scope of delivery ............................ 3 Contact ..............................3 Symbols used ............................3 Safety-related information ....................3 Intended use ............................3 Warnings ..............................3 Safety instructions ..........................
  • Page 3: General Information

    Operational safety is only guaranteed if the product is used as intended. Applicable documents The Regumaq X-80 potable water circulation set is used to Consult the following supplementary instructions: connect circulation pipes for the supply of hot potable water to the Oventrop Regumaq X-80 fresh water stations.
  • Page 4: Safety Instructions

    Regumaq X-80 Potable water circulation set Safety-related information Safety instructions 2.3.6 Damage to property due to unsuitable location We have developed this product in accordance with current safety requirements. Do not install the product in rooms prone to Observe the following instructions for safe use.
  • Page 5: Technical Description

    The use of circulation systems avoids this delay. Lateral connection for ball valve The Oventrop circulation set adds a circulation function to the Regumaq X-80 fresh water station. One pipe leads Ball valve from the fresh water station to the draw-off point and a parallel pipe leads back.
  • Page 6: Alternative Placement Of The High-Efficiency Pump And Ball Valve

    Regumaq X-80 Potable water circulation set Technical description 3.3.2 Alternative placement of the high- Piping efficiency pump and ball valve High-efficiency pump Piping Ball valve Technical data General information p s ) Max. 10 bar Operating pressure ( Operating temperature ( t s ) Max.
  • Page 7: Transport And Storage

    Regumaq X-80 Potable water circulation set Transport and storage 4. Transport and storage Slowly close the shutoff ball valve in the hot potable water return (position in Fig. 2 on page 5). Unscrew the cap of the fill and drain ball valve for hot Temperature range 0 °C to +40 °C...
  • Page 8: Electrical Connection Of The High-Efficiency Pump

    Regumaq X-80 Potable water circulation set Commissioning 6. Commissioning Electrical connection of the high- efficiency pump Configuration of the circulation For details on connecting the high-efficiency function pump, consult the instructions for the product you have selected. Configure the circulation function according to the...
  • Page 9: Maintenance

    Regumaq X-80 Potable water circulation set Maintenance Maintenance 8. Troubleshooting Functional check of the check valve MALFUNCTION CAUSE REMEDY The check valve prevents the potable water from The high-effi- The power sup- Check the pow- flowing back against the direction of circulation.