Electrostatics Discharge (Esd) - Hitachi CML176SXW Service Manual

Tft lcd monitor
Table of Contents

Advertisement

11.2 Electrostatics Discharge (ESD)

This test follow the IEC 61000-4-2
Discharge Voltage Level :
Criteria
Class C
Class B
Class A
Class A : Temporary degradation or loss of function or performance which requires
Class B : Temporary degradation or loss of function or performance which is self-
Class C : Normal performance within the specification limits
Discharge times: 20 times for each discharge point, time interval 1 second.
In the case of acceptance tests, the test program and the interpretation of the test results are
subject to
agreement between manufacturer and user.
The test documentation shall include the test conditions and the test results.
Contact Discharge (KV)
±4
±6
±8
operator Intervention or system reset.
recoverable
E.S.D Test
Air Discharge (KV)
43
±4
±8
±15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cml178sxwb

Table of Contents