9. POWER LINE SURGE TEST (IEC 61000-4-5 SURGE)

9.1 Climatic Condition

The climatic conditions shall be within the following ranges:
9.1.1
Ambient Temperature: 15
9.1.2
Relative Humidity: 10% to 75%
9.1.3
Atmospheric Pressure 86kPa (860mbar) to 106kPa (1060mbar)
Note: The temperature and relative humidity should be recorded in the test report.

9.2 Test Conditions:

9.2.1
Wave-shape of the current surge: (refer to IEC 61000-4-5)
Open circuit voltage:
Short circuit current:
9.2.2
Polarity:
9.2.3
Phase shifting:in a range between 0º to 270º versus the AC line phase angle
9.2.4
Repetition rate:at least 1 per minute
9.2.5 Number of tests: at least 5 positive and 5 negative at the selected points.
9.3
The surge will be applied between lines and between lines and ground.
9.4
If not otherwise specified, the surge to power supply circuits shall be applied synchronized
to the voltage phase at the zero crossing and the peak value of the AC voltage wave.
(Positive and negative)
9.5
The surge voltage for test is from 1KV and increases 1KV for each step.
9.6
The recommended severity levels for the surge voltage test is 2.0KV and without any
degradation or loss of function that is not recoverable due to damage of component or
software allowed.

Display set high-resolution mode, AC input use AC 240V

9.7
°
C to 35
(1.2 / 50 µs)
(8 / 20 µs)
positive / negative
°
C